Appendix A Safety Requirements
9/12
APPENDIX A SAFETY REQUIREMENTS
•
Any tester, equipment, or tool used at any production step, or for any
manipulation of semiconductor devices, have its shield connected to ground.
•
The product must be placed on a conductive table top, made of steel or clean
aluminum, or covered by an antistatic surface (superficial resistivity equal to or
higher than 0.5 M
Ω/cm
2
), grounded through a ground cable (conductive cable
from protected equipment to ground isolated with a 1 M
Ω resistor placed in
series). All manipulation of finished goods must be done at such a grounded
worktable.
•
The worktable free of all non-antistatic plastic objects.
•
An antistatic floor covering grounded through a conductive ground cable (with
serial resistor between 0.9 and 1.5 M
Ω) should be used.
•
It is recommended that you wear an antistatic wrist or ankle strap, connected to
the antistatic floor covering or to the grounded equipment.
•
If no antistatic wrist or ankle strap is worn, before each manipulation of the
powered-on tool, you touch the surface of the grounded worktable.
•
It is recommended that antistatic gloves or finger coats be worn.
•
It is recommended that nylon clothing be avoided while performing any
manipulation of parts.