21 - ENG

PROBLEM

CAUSE

CORRECTION

Compressor is

not supplying

enough air

to operate

accessories

Prolonged excessive

use of air.

Decrease amount of air usage.

Compressor is not

large enough for

air requirement.

Check the accessory air

requirement. If it is higher than

the SCFM or pressure supplied

by your air compressor, you

need a larger compressor.

Hole in hose.

Check and replace if required.

Check valve restricted.

Remove and clean, or replace.

Air leaks.

Tighten fittings.

Restricted air intake filter. Clean or replace air intake filter. Do not

operate the air compressor with the

filter removed. Refer to the

Air Filter

paragraph in the Maintenance section.

Loose belt.

Loosen wingnut and then

tighten wingnut until it contacts

the washer, plus one turn.

Restricted

air intake

Dirty air filter.

Clean or replace. See

Air Filter

paragraph in the Maintenance section.

Motor will

not run

Motor overload

protection switch

has tripped.

Refer to

Motor Overload Protection

under Operation. If motor overload

protection trips frequently, contact

a Trained Service Technician

Tank pressure exceeds

pressure switch

"cut-in" pressure.

Motor will start automatically when

tank pressure drops below "cut-

in" pressure of pressure switch.

Check valve stuck open. Remove and clean, or replace.
Loose electrical

connections.

Check wiring connection inside

pressure switch and terminal box area.

Possible defective motor

or starting capacitor.

Have checked by a Trained

Service Technician.

Paint spray on internal

motor parts.

Have checked by a Trained Service

Technician. Do not operate the

compressor in the paint spray area.

See flammable vapor warning.

Pressure release valve on

pressure switch has not

unloaded head pressure.

Bleed the line by pushing the

lever on the pressure switch to

the "Off" position; if the valve

does not open, replace switch.

Motor will not

run (continued)

Fuse blown, circuit

breaker tripped.

1. Check fuse box for blown fuse

and replace as necessary. Reset

circuit breaker. Do not use a fuse

or circuit breaker with higher

rating than that specified for

your particular branch circuit.

2. Check for proper fuse. You

should use a time delay fuse.

3. Check for low voltage conditions

and/or proper extension cord.

4. Disconnect the other electrical

appliances from circuit or

operate the compressor on

its own branch circuit.