18 - ENG

SERVICE AND ADjUSTMENTS

ALL MAINTENANCE AND REPAIR OPERATIONS NOT LISTED MUST BE

PERFORMED BY TRAINED SERVICE TECHNICIAN.

Risk of unsafe operation. Unit cycles automatically when

power is on. When servicing, you may be exposed to voltage sources, com-

pressed air, or moving parts. Before servicing unit unplug or disconnect elec-

trical supply to the air compressor, bleed tank of pressure, and allow the air

compressor to cool.

TO REPLACE OR CLEAN CHECk VALVE

1. Release all air pressure from air tank. See

To Drain Tank in the Maintenance

section.

2. Turn air compressor off, lock out the power supply, and relieve all air pres-

sure from the air tank.

3. Using an adjustable wrench loosen outlet tube nut at air tank and pump.

Carefully move outlet tube away from check valve.

Nut

Pressure

Relief

Tube

Check

Valve

Nut

Outlet

Tube

Nut

4. Using an adjustable wrench loosen pressure relief tube nut at air tank. Carefully

move pressure relief tube away from check valve.

5. Unscrew the check valve (turn counterclockwise) using a 7/8" open end

wrench.

NOTE the orientation for reassembly.

6. Using a screwdriver, carefully push

In closed position

disc is visible.

In open

position

nothing is

visible.

Screwdriver

the valve disc up and down.

NOTE:

The valve disc should move freely up

and down on a spring which holds

the valve disc in the closed position,

if not the check valve needs to be

cleaned or replaced.

7. Clean or replace the check valve.

A solvent, such as paint or varnish

remover can be used to clean the

check valve.

8. Apply sealant to the check valve threads. Reinstall the check valve (turn clock-

wise).

9. Replace the pressure release tube. Tighten nuts.
10. Replace the outlet tube and tighten nuts.
11. Perform the Break-in Procedure. See

Break-in Procedure in the Operation

section.