beautypg.com

Troubleshooting – Porter-Cable N028591 User Manual

Page 20

background image

20 - ENG

TROUBLESHOOTING

Risk of Unsafe Operation. Unit cycles automatically when

power is on. When servicing, you may be exposed to voltage sources, com-

pressed air, or moving parts. Before servicing unit unplug or disconnect elec-

trical supply to the air compressor, bleed tank of pressure, and allow the air

compressor to cool.

PROBLEM

CAUSE

CORRECTION

Excessive

tank pressure

- safety valve

pops off

Pressure switch does

not shut off motor when

compressor reaches

"cut-out" pressure.

Move Auto/Off lever to the "Off"

position, if the unit does not shut off

contact a Trained Service Technician.

Pressure switch "cut-

out" too high.

Contact a Trained Service Technician.

Air leaks at

fittings

Tube fittings are not

tight enough.

Tighten fittings where air can be

heard escaping. Check fittings

with soapy water solution. DO

NOT OVER TIGHTEN.

Air leaks at

or inside

check valve

Check valve seat

damaged.

A defective check valve results in

a constant air leak at the pressure

release valve when there is pressure in

the tank and the compressor is shut

off. Replace check valve. Refer the

To

Replace or Clean Check Valve in

the Service and Adjustments section.

Air leaks at

pressure switch

release valve

Defective pressure

switch release valve.

Contact a Trained Service Technician.

Air leaks in air

tank or at air

tank welds

Defective air tank.

Air tank must be replaced.

Do not repair the leak.

Risk of bursting.

Do not drill into, weld or otherwise

modify air tank or it will weaken. The

tank can rupture or explode.

Air leaks

between head

and valve plate

Leaking seal.

Contact a Trained Service Technician.

Pressure

reading on

the regulated

pressure gauge

(if equipped)

drops when

an accessory

is used

It is normal for "some"

pressure drop to occur.

If there is an excessive amount of

pressure drop when the accessory

is used, adjust the regulator as

instructed in the Operation section.
NOTE: Adjust the regulated

pressure under flow conditions

(while accessory is being used).

Air leak from

safety valve

Possible defect in

safety valve.

Operate safety valve manually

by pulling on ring. If valve still

leaks, it should be replaced.

This manual is related to the following products: