Characteristics – Philips BGY148A User Manual
Page 3
1998 May 13
3
Philips Semiconductors
Product specification
HF amplifier modules
BGY148A; BGY148B
CHARACTERISTICS
Z
S
= Z
L
= 50
Ω
; P
D
= 10 mW; V
S
= 6 V; V
C
≤
3.5 V; T
mb
= 25
°
C; unless otherwise specified.
SYMBOL
PARAMETER
CONDITIONS
MIN.
TYP.
MAX.
UNIT
f
frequency range
BGY148A
400
−
440
MHz
BGY148B
430
−
488
MHz
I
Q
total quiescent current
V
C
= 0; P
D
= 0
−
−
100
µ
A
I
C
control current
adjust V
C
for P
L
= 3 W
−
−
500
µ
A
P
L
load power
3
−
−
W
G
p
power gain
adjust V
C
for P
L
= 3 W
24.8
−
−
dB
η
efficiency
adjust V
C
for P
L
= 3 W
46
53
−
%
H
2
second harmonic
adjust V
C
for P
L
= 3 W
−
−
−
38
dBc
H
3
third harmonic
adjust V
C
for P
L
= 3 W
−
−
−
38
dBc
VSWR
in
input VSWR
adjust V
C
for P
L
= 3 W
−
−
3 : 1
control range
V
C
= 0 to 3.5 V
10
−
−
dB
stability
P
D
= 5 to 20 mW; V
S
= 5 to 8.5 V;
P
L
≤
3.5 W;
VSWR
≤
4 : 1 through all phases
−
−
−
60
dBc
ruggedness
V
S
= 8.5 V; adjust V
C
for P
L
= 3.5 W;
VSWR
≤
4 : 1 through all phases
no degradation
Fig.2 Load power derating curves.
V
S
= 8.5 V.
handbook, halfpage
0
100
5
0
1
2
3
4
PL
(W)
Tmb (
o
C)
20
40
60
80
MDA207
VSWR = 3:1
VSWR = 1:1