beautypg.com

Protected mastercolor, Lamp technology, Electrical data – Philips MasterColor 377200 User Manual

Page 2: Warnings, cautions and operating instructions, Lamp operating instructions

background image

(1)

Measured at 100 hours of life in vertical position.

(2)

Measured at rated lamp watts on a linear reactor. LPW does not include ballast losses.

(3)

Measured with the lamp operating at rated watts.

Electrical Data

(Subject to change without notice)

Warnings, Cautions and Operating Instructions

“WARNING:These lamps can cause serious skin burn and eye inflammation
from short wave ultraviolet radiation if outer envelope of the lamp is broken or
punctured. Do not use where people will remain for more than a few minutes
unless adequate shielding or other safety precautions are used. Certain lamps
that will automatically extinguish when the outer envelope is broken or punctured
are commercially available.” This lamp complies with FDA radiation performance
standard 21 CFR subchapter J. (USA:21CFR 1040.30 Canada:SOR/DORS/80-381)

If the outer bulb is broken or punctured, turn off at once and replace the lamp
to avoid possible injury from hazardous short wave ultraviolet radiation. Do not
scratch the outer bulb or subject it to pressure as this could cause the outer bulb
to crack or shatter.A partial vacuum in the outer bulb may cause glass to fly if the
envelope is struck.

WARNING:The arc-tube of metal halide lamps are designed to operate under high
pressure and at temperatures up to 1000ºC and can unexpectedly rupture due to
internal or external factors such as a ballast failure or misapplication. If the arc-tube
ruptures for any reason, the outer bulb may break and pieces of extremely hot
glass might be discharged into the surrounding environment. If such a rupture
were to happen,THERE IS A RISK OF PERSONAL INJURY, PROPERTY DAMAGE,
BURNS AND FIRE.

These lamps are designed to retain all the glass particles should an arc tube rup-
ture occur. The following operating instructions are recommended to minimize
these occurrences.

RELAMP FIXTURES AT OR BEFORE THE END OF RATED LIFE. Allowing lamps
to operate until they fail is not advised and may increase the possibility of inner
arc tube rupture.

This lamp contains an arc tube with a filling gas containing Kr-85 and is distributed
by Philips Lighting Company, a division of Philips Electronics North America
Corporation, Somerset, New Jersey 08875-6800.

CAUTION: TO REDUCE THE RISK OF PERSONAL INJURY, PROPERTY
DAMAGE, BURNS AND FIRE RESULTING FROM AN ARC-TUBE RUPTURE
THE FOLLOWING LAMP OPERATING INSTRUCTIONS MUST BE FOLLOWED.

Lamp Operating Instructions:

1) RELAMP FIXTURES AT OR BEFORE THE END OF RATED LIFE.Allowing

lamps to operate until they fail is not advised and may increase the possibility
of inner arc tube rupture.

2) Before lamp installation/replacement, shut power off and allow lamp and

fixture to cool to avoid electrical shock and potential burn hazards.

3) Use only auxiliary equipment meeting Philips and/or ANSI standards.

Use within voltage limits recommended by ballast manufacturer.

A. Operate lamp only within specified limits of operation.

B. For total supply load refer to ballast manufacturers electrical data.

4) Periodically inspect the outer envelope. Replace any lamps that show scratches,

cracks or damage.

5) If a lamp bulb support is used, be sure to insulate the support electrically to

avoid possible decomposition of the bulb glass.

6) Protect lamp base, socket and wiring against moisture, corrosive atmospheres

and excessive heat.

7) Time should be allowed for lamps to stabilize in color when turned on for the

first time. This may require several hours of operation, with more than one
start. Lamp color is also subject to change under conditions of excess vibration
or shock, and color appearance may vary between individual lamps.

8) Lamps may require 10 to 20 minutes to re-light if there is a power interruption.

9) Take care in handling and disposing of lamps. If an arc tube is broken, avoid skin

contact with any of the contents or fragments.

*This “Provisional Data” is subject to change before a permanent

“Technical Data Sheet” is issued.

Philips Lighting Company
200 Franklin Square Drive

P.O. Box 6800

Somerset, NJ 08875-6800
1-800-555-0050
www.lighting.philips.com/nam

A Division of Philips Electronics North America Corporation
Printed in USA 2/01

MHCP 014

Philips Lighting
281 Hillmount Road
Markham, Ontario L6C 2S3

A Division of Philips Electronics Limited

Lamp Watts (Nominal) . . . . . . . . . . . . . . . . . . . . . . . . . 150
Lamp Operating Voltage (rms) (Nominal)

(2)

. . . . . . . . .

95

Initial Lamp Voltage Range (rms)

(3)

. . . . . . . . . . . . . . . .

85–105

Lamp Operating Current (Amps) (rms) (Nominal). . . . 1.5
Lamp Current Crest Factor (Maximum). . . . . . . . . . . . 1.8
Warm-up Time to 80% of Output . . . . . . . . . . . . . . . . 2 Minutes
Re-strike Time for Hot Lamp . . . . . . . . . . . . . . . . . . . . 4–8 Minutes
Ballast Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ANSI M102/M142
Ballast Open Circuit Voltage (Minimum) . . . . . . . . . . . . 382 RMS, 540 Peak
Pulse Peak Volts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3300 Min., 4000 Max.
Pulse Width @ 90% Peak. . . . . . . . . . . . . . . . . . . . . . . 2 Micro Second Minimum
Pulse Repetition Rate (Minimum) . . . . . . . . . . . . . . . . . 2 per Half Cycle
Minimum Operating Temperature. . . . . . . . . . . . . . . . . -30º C

Protected MasterColor

®

Metal Halide 150 Watt ED-17P 4K (Coated) Lamp Featuring ALTO

®

Lamp Technology

Philips
Lighting
Company