Pitco Frialator CPE14 User Manual
Page 10
![background image](/manuals/185910/10/background.png)
3-4
m. Reinstall the front panel.
n. Close drain.
o. Close the door.
p. Reconnect the cooker to the facility power source.
3.3.2 Limit Control Replacement
The limit control includes a temperature sensor inside the tank, a control unit inside the cooker
cabinet, and connecting capillary tubing.
CAUTION
The limit control capillary tubing is very delicate. Be VERY CAREFUL
when working with the capillary tubing. The limit control is no longer usable
if the tubing is kinked or broken.
a. Disconnect the cooker from the facility power source.
b. Drain the water from the cooker and remove the element rack assembly.
c. The limit control probe (heat sensor) is clamped to the heating element inside the tank.
Unscrew and remove the two screws in the probe clamp.
d. Remove the probe from the clamp and straighten the capillary tubing.
e. Unscrew the small hex nut inside the cabinet at the front of the tank for the limit control.
f. Unscrew the large connector nut from the tank and pull the probe and capillary tubes
through the opening.
g. Remove the two mounting screws from the limit control bracket and remove the limit
control unit, located behind the front panel.
h. Install a new limit control unit by connecting the wires.
i. Place the limit control unit in the limit control bracket.
j. Install and tighten the two mounting screws.
k. Insert the probe and capillary tubes through the opening in the tank.