Adjusting the camera – Philips WV-NW484S User Manual
Page 28
28
Adjusting the Camera
1
Adjust the camera angle while
monitoring the image on the
adjustment monitor.
Connect the adjustment monitor
(small LCD monitor, etc.) to the
monitor output terminal, and adjust
the camera angle.
Determine and set the camera angle
while repeating the fine-adjustments
in steps (1), (2) and (3) below.
(1) Loosen the pan lock screw, and
rotate the camera horizontally to
adjust pan.
(2) Loosen the 2 tilt lock screws, and
rotate the camera vertically to
adjust tilt.
(3) Turn the tilt adjustment seat to
adjust the screen tilt.
(4) When the camera angle is
determined, tighten the pan lock
screw and the tilt lock screws.
..............................................................................................................................
Note
• Also adjust the focus in step 2 during pan and tilt adjustment.
...................................................................................................................................
Important
• Be sure to tighten the panning lock screw (recommended torque: 0.59N·m {6 kgf·cm}).
(1) Pan lock screw
(2) Tilt lock screw
Monitor output connector
(mini-jack)
75°
(3) Tilt adjustment seat
Panning table