beautypg.com

Troubleshooting – Planet Technology FSD-1603 User Manual

Page 15

background image

1

4. TROUBLESHOOTING

This chapter contains information to help you solve problems. If the Switch is not
functioning properly, make sure the Fast Ethernet Switch was set up according to
instructions in this manual.

The per port LED is not lit

Solution:

Check the cable connection of the FSD-503 / FSD-803 / FSD-1603.

Performance is bad

Solution:

Check the speed duplex mode of the partner device. The FSD-503 / FSD-803 /
FSD-1603 are run at Auto-negotiation mode and if the partner is set to half duplex,
then the performance will be poor.

Per port LED is lit, but the traffic is irregular

Solution:

Check that the attached device is not set to dedicate full duplex. Some devices use
a physical or software switch to change duplex modes. Auto-negotiation may not
recognize this type of full-duplex setting.

Why the Switch doesn’t connect to the network

Solution:

Check per port LED on the Switch. Try another port on the Switch Make sure the
cable is installed properly Make sure the cable is the right type Turn off the power.
After a while, turn on power again.

This manual is related to the following products: