11.0 Commissioning

© Baxi Heating UK Ltd 2008

11.2

Checking

1. The gas valve is factory set and the burner pressure cannot

be measured as it is altered by suction of the fan and

modulates as demand on the boiler alters. The gas supply

pressure should be 20mb.

2. If necessary the gas rate may be checked after running the

boiler for 10 minutes with any other appliances and pilot

lights turned off.

3. Ensure that the integral timer and any external controls are

calling for heat, and the selector switch is in the central

heating and hot water position ( ). The current boiler

temperature is shown on the display.

4. To check the gas rate it is necessary to set the boiler to

‘Calibration Mode’.

5. Turn both temperature control knobs fully anticlockwise,

then quickly turn the DHW temperature knob

1

/

4

clockwise

twice and back fully anticlockwise (Fig. 66).

6. The display will now alternate between ‘SF’ and the

current boiler temperature and both green LEDs will flash

(Figs. 67 & 68).

7. Turn CH temperature control knob fully clockwise. As the

knob is turned the display will change from ‘0’ to ‘00’ (Fig. 69)

indicating maximum rate, then revert to ‘P’ alternating with

the current boiler temperature (Figs 70 & 71).

8. A gas rate measurement may now be made. Approximate

values are:-

24 model

2.6m

3

/h

28 model

3.1m

3

/h

33 model

3.6 m

3

/h

9. The ‘Calibration Function’ is active for 20 minutes unless

the maximum CH temperature is exceeded.

10. The function can be disabled at any time by turning the

DHW temperature knob.

Selector Switch

Display

Reset

1

2

3

4

5

P

M

7

8

9

10

11

12

1

2

3

4

5

AM

7

8

9

10

11

12

0

bar

0

1

2

3

4

Central Heating

Temperature Control

Domestic Hot Water
Temperature Control

Fig. 67

Fig. 68

Fig. 69

Fig. 70

Fig. 71

Central Heating

Temperature Control

Domestic Hot Water
Temperature Control

Fig. 66

x 2