8.0 Flue Options

For Twin Flue Systems fit the adaptors as follows:-

8.4

Flue Duct Adaptor

1. Engage the flue duct adaptor on the boiler adaptor,

making sure that it is pushed down as far as possible.

8.5

Air duct adaptor

1. Undo the screws securing the blanking plate to the boiler

top panel. Discard the plate.

2. There are three restrictor plates supplied in the kit. One

marked ‘23’ and one marked ‘27’, these can be discarded

The third restrictor MUST be positioned as shown in the

diagrams below.

3. Take one of the gaskets supplied in the kit and place on

the boiler top panel.

4. Align the appropriate restrictor as shown. Position the

second gasket over the restrictor.

5. Using the screws previously removed secure the inlet

adaptor to the top panel.

6. Continue to fit the twin flue system.

Flue Duct Adaptor

Boiler Adaptor

Air Duct Adaptor

Gasket

Restrictor

Gasket

Position of Restrictor

Blanking Plate

24 kW models

28/33 kW models