beautypg.com

Pelco CAMCLOSURE C2410M-G User Manual

Page 9

background image

Pelco Manual C2410M-G (1/04)

[ 9 ]

NOT USED

= SWITCH POSITION

FACTORY SETTINGS

ALC

Y

BLC

ABL

ELC

DC

OFF

OFF

01061

ON

OFF

Switch Settings for Fixed Focal Length Lens
Without Auto Iris

Refer to the switch drawing. The switch is located next to the lens. Automatic backlight compensation
(factory setting) is used under varying lighting conditions (such as outdoors) or fixed lighting conditions
where there are no bright spots that darken other picture details. Manual backlight compensation is used
in fixed lighting conditions to optimize the picture detail when there are bright spots.

ALC/ELC switch:

Always ELC

Y/DC switch:

Not used

Auto backlight compensation:

BLC switch OFF
ABL switch ON

Manual backlight compensation: BLC switch ON

ABL switch OFF

Switch Settings for Fixed Focal Length Lens with
Auto Iris

Refer to the switch drawing. The switch is located next to the lens. Automatic backlight compensation
(factory setting) is used under varying lighting conditions (such as outdoors) or fixed lighting conditions
where there are no bright spots that darken other picture details. Manual backlight compensation is used
in fixed lighting conditions to optimize the picture detail when there are bright spots.

ALC/ELC switch:

Always ALC

Y/DC switch:

Always DC

Auto backlight compensation:

BLC switch OFF
ABL switch ON

Manual backlight compensation: BLC switch ON

ABL switch OFF

= SWITCH POSITION

FACTORY SETTINGS

ON

OFF

ALC

Y

BLC

ABL

ELC

DC

OFF

OFF