Quiet operation – Panasonic CU-C12DKU User Manual
Page 25

8.10. Quiet Operation
(For Cooling Operation or cooling region of Soft Dry Operation)
•
The Quiet operation is to provide quiet/cooling operation condition compare to normal operation.
•
Once the Quiet Mode is set at the remote control, the Quiet Mode LED illuminated. The sound level will reduce around 2 dB
for Lo fan speed or 3 dB for Hi/Me fan speed against the present operation sound level.
•
Dew formation become severe at Quiet Lo cool, therefore Quiet Lo cool is operated only 1hr 30 min (1hr QLo, 30 min QLo +
80 rpm). After that, it goes back to Lo cool (However Quiet LED remains on).
•
Manual Airflow Direction:-
−
RPM control during Lo cool
−
RPM control during Hi cool
•
Auto Airflow Direction:-
•
Quiet operation stops when:-
−
Quiet button is pressed again.
−
Stopped by OFF/ON operation button.
−
Timer OFF activates.
−
Powerful button is pressed.
−
Economy button is pressed.
−
Operation mode button is changed.
25
CS-C9DKU CU-C9DKU / CS-C12DKU CU-C12DKU