MAX PRO-SERIES Communication/Configuration Specifications (continued)
USA & Canada (800) 472-5555 • (707) 283-5900 • Fax (707) 283-5901
11
Sets the feedback to ON (unsolicited) or OFF
(polled). When ON, a message will be sent to
the controller every time the status of an input
(i.e. trigger), output (i.e. outlet) or power state
(i.e. overvoltage) changes. If feedback is OFF,
the controller must request feedback.
Controls the linefeeds (ASCII: 10d, 0Ah) sent
with each response. When ON, each response
will end with a linefeed. When OFF, all respons-
es will not end with a linefeed.
Resets all of the custom configuration settings
(i.e. triggers, delays, meter brightness, feed-
back mode, & linefeed mode) to their original
factory settings listed below.
Resets the configuration below:
TRIGGER FOR 1 = BUTTON
TRIGGER FOR 2 = BUTTON
TRIGGER FOR 3 = BUTTON
TRIGGER FOR 4 = BUTTON
TRIGGER FOR HC1 = BUTTON
TRIGGER FOR HC2 = BUTTON
TRIGGER FOR TRIGOUT = TRIGIN
DELAY FOR 1 = 000,005
DELAY FOR 2 = 001,004
DELAY FOR 3 = 002,003
DELAY FOR 4 = 003,002
DELAY FOR HC1 = 004,001
DELAY FOR HC2 = 005,000
DELAY FOR TRIGOUT = 005,000
BRIGHTNESS = 100
FEEDBACK = ON
LINEFEED = ON
1.9
!SET_FEEDBACK mode
mode = { ON, OFF }
1.10
!SET_LINEFEED mode
mode = { ON, OFF }
1.11
!RESET_ALL
If mode = ON, $FEEDBACK = ON
If mode = OFF, $FEEDBACK = OFF
If mode is invalid, $INVALID_PARAMETER
If mode = ON, $LINEFEED = ON
If mode = OFF, $LINEFEED = OFF
If mode is invalid, $INVALID_PARAMETER
$FACTORY SETTINGS RESTORED
Command String
Action Response
- Lan/UTP 5E Module BANKS WIRING MB1000 MB1500 Rackmount UPS, Voltage Regulator & Power Conditioner 2-Outlet Direct Plug-In Surge Protector with Tel/LAN Connectors 2-Outlet Direct Plug-In Surge Protector (End-to-End) 2-Outlet Direct Plug-In Surge Protector with Coaxial In/Out MAX 5400-EX Max 5400 Power Line Management with Voltage Regulation (2 RU, 11 Outlets) MR4000 Power Management System MAX M5300-EX