Dip switch – Panasonic VQT0F74 User Manual
Page 52
– 52 –
DIP switch
AV microcomputer DIP switch specifications
SW6501
1
2
3
4
5
6
7
8
ON (0)
Normal
Normal
——
OFF (1)
Normal
Normal
Normal
Normal
——
——
Normal
Normal
Remarks
Not used
Not used
Not used
Not used
Keep this switch at the factory setting.
Keep this switch at the factory setting.
Keep this switch at the factory setting.
Keep this switch at the factory setting.
Remarks
Keep it at the factory setting.
For test purposes.
[This sets whether to accept or prohibit the selection of
the editing mode when the X-value adjustment master
tape (D3 recorded tape) has been loaded.]
For test purposes.
The D3 cassette holes are detected, and the cassette
is forcibly ejected automatically.
For test purposes.
For test purposes.
SW6071
1
2
3
4
6
7
8
ON
Normal
Ejected
——
——
OFF
Normal
Prohibited
Normal
Not ejected
Normal
Normal
SYSCON microcomputer DIP switch specifications
History: No.6: From SYSCON Ver.0.12
The underlining indicates the factory settings.
SERVO microcomputer DIP switch specifications
SW2001
1
2
3
4
Purpose
For AT adjustments
For AT adjustments
For AT adjustments
For AT adjustments
ON
When adjusting
When adjusting
When adjusting
When adjusting
OFF
At all other times
At all other times
At all other times
At all other times
CAUTION:
These servicing instructions are for use by qualified service personnel only. To reduce the risk of
electric shock do not perform any servicing other than that contained in the operating instructions
unless you are qualified to do so.