beautypg.com

Pitco Frialator I8 Water Cooker Computer User Manual

Page 11

background image

I8 Water Cooker Computer Service

Pitco P/N PP11375

L22-303 Rev 0 (01/07)

11

7

8

1

2

4.6 Recovery Test Value:

This control records the heat up time for the appliance. A poorly running appliance will have an
increased recovery time. Select this menu option to view the last recorded recovery time for this
appliance. The recovery time is the length of time(in seconds) the appliance needs to heat the
vat from 230

°F to 280°F. This menu option is for display only.

With the control display showing [SERVICE ], press product key 7. The control display will
show [Rxxx-yyy], where xxx is the last recorded recovery time for this appliance, and yyy
is the factory default recovery time. Press the program key to exit it out of this menu
option. The display will now show [SERVICE ]. Continue on to the remaining service menu
options below, or press the program key twice to return to normal operation(display shows either
[READY], [ACT xxx’F], or [FILLING ]).

4.7 More Service Menu Options:

With the control display showing [SERVICE ], press product key 8. The display will show
[MORE ] for the More Service Menu.

The key indicators that light up will have options that can be adjusted. Any key indicators
that do not light up do not have options that can be adjusted.

All of the Level 3 More Service Menu programming options shown below must begin with the
control displaying this prompt [MORE ].

4.7.1

Low Ready Level Adjustment:

This setting allows the READY idle message to be displayed a number of degrees below
the current set temperature. For example, if the current set temperature is 180

°F, and

the READY idle display message is to be displayed from 175

°F to 180°F, then this

setting should be given a value of 5. The maximum value for this setting is 9 degrees.

With the control display showing [MORE ], press product key 1. The display will
now show [RDY LO x], where x is the current Low Ready Level setting. Enter the
new value using product keys 0-9. Press the program key to save this setting.
The display will now show [MORE ]. Continue on to the remaining more service
menu options below, or press the program key three times to return to normal
operation(display shows either [READY], [ACT xxx’F], or [FILLING ]).

4.7.2

High Ready Level Adjustment:

This setting allows the READY idle message to be displayed a number of degrees
above the current set temperature. For example, if the current set temperature is 180

°F,

and the READY idle display message is to be displayed from 180

°F to 185°F, then this

setting should be given a value of 5. The maximum value for this setting is 9 degrees.

With the control display showing [MORE ], press product key 2. The display will
now show [RDY HI x], where x is the current High Ready Level setting. Enter the
new value using product keys 0-9. Press the program key to save this setting.
The display will now show [MORE ]. Continue on to the remaining more service
menu options below, or press the program key three times to return to normal
operation(display shows either [READY], [ACT xxx’F], or [FILLING ]).