3 0

3 1

2nd gain

action set-up

Position control
switching mode

0 ~ 1

0 ~ 8

-----

---

Details of Parameters

Parameters for Switching to 2nd Gains

Gain selection and switching

Fixed to the 1st gains

*1 (switching between PI and P possible)

Switching between the 1st

and 2nd gains possible *2

GAIN input

COM- disconnected

COM- connected

Operation of the position loop

PI operation

P operation

Default : [ ]

Value

[ 0 ]

1

Conditions for gain switching

Fixed to the 1st gain

Fixed to the 2nd gain

2nd gain selection with the gain switching input (GAIN) ON/

(Pr30 must be set to 1)

2nd gain selection with a larger torque command change

Fixed to the 1st gain

2nd gain selection with a larger velocity command

2nd gain selection with a larger position error

2nd gain selection with the position command issued

2nd gain selection with existence of 1 or more command pulse in 166 É s area.

2nd gain selection with no in-position

2nd gain selection with a position error counter value larger than Pr60 (in-

position detection range)

Value

[ 0 ]

1

2

3

4

5

6

7

8

*

3 For the switching level and timing, see App. 54 and App. 55.

*