beautypg.com

Window requirements requisitos de la ventana – Panasonic CW-C100AU User Manual

Page 9

background image

7

• Hot sun rays hitting the outside surface of the cabinet will create considerable heat

load. If the outside of the cabinet is in direct sunlight, consider building an awning to
shade the cabinet while providing ample area for the heated air to be exhausted from
the condenser (both sides) and the top.
This unit is designed for installation in standard double hung windows.

NOTE: The unit may also be installed “through the wall”. You should, however,

observe standard carpentry practices and frame the opening without violating
local ordinances.

• Los rayos solares que tocan la superficie exterior de la caja crearán una considerable

carga de calor. Si la parte que da al exterior de la caja está bajo la luz directa del sol,
considere el construir un toldo para dar sombra pero dejando espacio suficiente para
que el aire caliente pueda ser expulsado del condensador (en ambos lados) y parte
superior.
Este aparato está diseñado para ser instalado en ventanas levadizas dobles.

NOTA: Esta unidad tambíen se puede instalar a través de la pared. En este caso, se

deberán realizar trabajos de carpintería y construir una estructura en la abertura
deacuerdo con los reglamentos locales.

WINDOW REQUIREMENTS

REQUISITOS DE LA VENTANA

22

to 42-

1

/

8

22

a 42-

1

/

8

PREPARATION OF AIR CONDITIONER CHASSIS
PREPARACIÓN DEL CHASIS DEL ACONDICIONADOR DE AIRE

CLOSE VENT

OPEN

Pull up the front intake grille about 90° and slide it slightly
to the left to unhook the tabs.
Tire la rejilla frontal cerca de 90° y deslice un poco a la
izquierda para desenganchar la etiqueta.

CLOSE VENT

OPEN

CLOSE VENT

OPEN

Air filter

Filtro de aire

Tilt up and pull out the air filter by the holder.

Incline y saque el filtro por el soporte.

SELECT THE BEST LOCATION
(Single or Double hung window)
ELIJA LA MEJOR UBICACIÓN
(Ventana de guillotina simple o doble)

Front grille

Rejilla frontal

Indoor side

Lado interior

19–

3

/

16

inches

19–

3

/

16

pulgadas

CLOSE VENT

OPEN

Window

Ventana

SIDE VIEW
VISTA LATERAL

Front grille

Rejilla frontal

Window

Ventana

Outdoor side

Lado exterior

12 inches

12 pulgadas

12 inches

12 pulgadas

More than 4 inches

Más de 4 pulgadas

NOTE: It is much easier, and also safer, to install the

empty cabinet into a window first and we
would suggest that you follow this procedure.

NOTA: Es mucho más fácil y también más seguro

instalar primero la caja vacía en la ventana.
Nosotros sugerimos, que lo haga así.

15-

15

/

16

(min)

15-

15

/

16

(minimo)

1

Remove the front intake grille

Quite la rejilla frontal de la toma de aire

2

Remove the air filter

Quite el filtro de aire