4.10 LEDs. There are 5 LEDs on the iSCSI Bridge that can be used for
status/diagnostics (see Image 2 of section 4.6)
4.10.1 SCSI Activity (Yellow). The SCSI Activity LED is labeled “SCSI” on
the iS520 and iS550. During normal operation, this LED turns on 
when there is SCSI activity on the SCSI bus. However, the LED will 
also indicate when there are no SCSI targets on the SCSI bus. After 
initial boot, i.e. after the Status LED has turned solid green, if the 
SCSI Activity LED is continuously blinking at a constant half second 
rate, the unit has found no targets on the SCSI bus. 
 
4.10.2 Status (Red/Green). The Status LED is labeled
 “STAT” on the iS520 and iS550. The Status LED identifies what 
 stage the boot process is in. It also notifies the user when an update is 
 being loaded into the unit by turning solid red. Once 
 the update is complete, the LED will return to a solid green state. 
 Please refer to table 3 below. 
 
Description
Color
State
Boot Loader
OFF
OFF
Operating System
N/A
SOLID
Network Interface
RED
5 BLINKS
Web-based Utility
RED
3 BLINKS
SCSI
RED
2 BLINKS
iSCSI
RED
4 BLINKS
Boot Complete
GREEN
SOLID
Updating Unit
RED
SOLID (During Burning)
Table 3
4.10.3 Power (Red/Green). The Power LED is labeled
 “PWR” on the iS520 and iS550. This LED will turn solid green when 
 there is sufficient power to the unit. The LED will turn off when the 
 unit is NOT powered. The LED will turn solid RED when the 
 immediate ambient temperature has exceeded 65°C. The unit will be 
 held in reset and the user will not be able to communicate with it once 
 in this state. If the user wishes to restart the unit first bring the 
 ambient temperature down to an acceptable level (<40°C), wait 10 
 minutes and press the reset button. 
4.10.4 Ethernet Data (Green). The Ethernet Data LED is labeled
 “DATA” on the iS520 and iS550. This LED turns on when there is 
 activity to/from the iSCSI Bridge on the Ethernet network. 
 
 