beautypg.com

Patton electronic 1004ABRC User Manual

Page 5

background image

7

8

S1-3: Reserved

Switch S1-3 is reserved and

must remain in the OFF position

.

S1-3

Setting

On

Not a Valid Setting

Off

Default Setting

S1-4: Echo Mode

The setting for switch S1-4 determines whether the Model

1004ABRC echoes data back to the transmitting device (half-duplex
mode only).

S1-4

Setting

On

Echo On

Off

Echo Off

SWITCH SET “S2”

DIP switch S2 is used to configure transmit impedance, and

2-wire/4-wire operations. The summary table below shows the factory
default settings for switch S2. Following the summary table is a
detailed description of each individual switch.

S2-1 and S2-2: “Transmit Off” Impedance

Switches S2-1 and S2-2 are set together to determine whether the

receiving device “sees” the impedance of the Model 1004ABRC’s trans-
mitter as being “high” or “intermediate” when the transmitter is turned
off. The “intermediate” setting is useful in half-duplex environments
where the receiving device does not respond well to the “high” setting.

S2-1

S2-2

Setting

On

On

Intermediate Impedance

Off

Off

High Impedance

S2-3 and S2-4: 2-wire/4-wire Modes

Switches S2-3 and S2-4 are set together to determine whether the

Model 1004ABRC is in 2-wire or 4-wire operating mode. Note: 2-wire
mode is half-duplex only.

S1-2

S1-3

Setting

On

On

2-wire mode

Off

Off

4-wire mode

3.1.2 SWITCH SETTINGS - MODEM “B”

DIP switches S3 and S4 configure short range Modem B on the

Model 1004ABRC front card. The tables below provide an overview of
Modem A switch settings, including factory default settings. Following
each figure is a detailed description of each switch’s function.

SWITCH SET “S3”

DIP switch S3 is used to configure receive impedance, RTS/CTS

delay and “echo” enable/disable. The summary table below shows the
factory default settings for switch S3.
Following the summary table is a detailed description of each individual
switch.

SWITCH S2 SUMMARY TABLE (factory defaults in bold)

Position

Function

ON Position

OFF Position

S2-1*

TX Impedance

Intermediate

High

S2-2*

TX Impedance

Intermediate

High

S2-3*

2-Wire/4-Wire

2-Wire

4-Wire

S2-4*

2-Wire/4-Wire

2-Wire

4-Wire

*Note:

Switches S2-1 and S2-2 must be switched simultaneously.

Switches S2-3 and S2-4 must be switched simultaneously.

SWITCH S3 SUMMARY TABLE (factory defaults in bold)

Position

Function

ON Position

OFF Position

S3-1

RX Impedance

120 Ohm

16K Ohm

S3-2

RTS/CTS Delay

8 msec

No Delay

S3-3

Reserved

-

Default Setting

S3-4

Echo Mode

Echo ON

Echo OFF