beautypg.com

Package and operating conditions, 1 package and operating conditions, Starter kit contents absolute maximum rating – Philips FMod-TCP BOX User Manual

Page 5: Preliminary, 1package and operating conditions, Starter kit contents, Absolute maximum rating

background image

5 / 58

1

Package and operating conditions

Starter Kit contents

The FMod-TCP BOX “Starter kit” should contain:

ƒ

FMod-TCP BOX device

ƒ

RS232 DSub cable

ƒ

DIN 41651 40 lines cable

ƒ

CD-Rom with dedicated software and Java applet sample

ƒ

This manual

Absolute maximum rating

Damage may occur if the device is operated using values beyond those
mentioned below; device operation is not guaranteed.

Preliminary

Parameter

Conditions

Min Typ Max Unit

Supply voltage

0

24

33

V

Supply current

No device connected to extension
connector.

60

100

mA

Supply current

Device(s) connected to extension
connector.

3 A

Outputs 1, 2 current

Relays.

1

A

Outputs 1, 2 voltage

Max voltage to GND.

50

V

Outputs 3-14 current

0.5

A

Outputs 15, 16 current

1

A

Inputs voltage

-15

28

V

+5V output current

Pin 17 on extension connector.

0.4

A

Power output current

Pin 40 on extension connector.

1

A

Operating temperature

0

70

°C

Storage temperature

-40

120

°C


All external pins are protected against destruction by ESD (2kV).

The power supply input is protected against over and inverted voltage by a
33V Zener diode. The protection is guaranteed during 10ms within the
following current values:

ƒ

For inverted voltage: 100A (the internal polifuse will cut the supply).

ƒ

For over voltage: 3.25A max (the diode will be destroyed before the

fuse after 10ms!).


Damages to the device due to over or inverted voltage are not covered by
the warranty.