beautypg.com

2 system reboot, 3 configuration setting – Planet Technology SVC2540 User Manual

Page 32

background image

-29-

Figure 4-15

Loop Back Reply /Enable screen

4.7.2 System Reboot

The Reboot page enables the device to be rebooted from a remote location. Once the Reboot button is pressed, users
have to re-login the WEB interface about 20 seconds later.

Figure 4-16

Reboot dialogue box screen

4.7.3 Configuration Setting

This function allows backup and restore the current configuration of FX-90x, or reset the converter to factory default. The
description of the three items as follow and screen in Figure 4-17 appears.

Backup -

To backup/save the current configuration to the storage block on this converter.

Restore –

To restore the previous backup configuration from the storage block.

Factory –

To reset the FT-90x back to the factory default mode.