21

22

5.5 POWER-DOWN

Turn off the Model 1065 Series by simply unplugging the AC power

cord from the wall. There is no power switch.

APPENDIX A

PATTON ELECTRONIICS MODEL 1065 SPECIFICATIONS

Transmission Format:

Synchronous or asynchronous, 2-
wire/half duplex, or 4-wire/full or half
duplex

Interface:

RS-232 (CCITT V.24) connection via
DB-25 female; twisted pair connection
via RJ-45

Transmission Line:

2 or 4-wire UTP, 19 - 26 AWG

Data Rates:

Model 1065 - Synchronous or
asynchronous at 1.2, 1.8, 2.4, 3.6, 4.8,
7.2, 9.6, 14.4, 19.2, 28.8, 38.4, 57.6 and
64 kbps—switch selectable;

Clocking:

Internal, external or receive recover

Controls:

Carrier constantly “ON” or “controlled by
RTS”; RTS/CTS delay set to no
delay, 7 or 53 ms

Applications:

Point-to-point or multi-point

Indicators:

Mono-color LED indicators for TD, RD,
RTS & DCD; single LED indicators for
Power, Test, and Error

RTS Anti-stream Timer

12.5 sec., 50 sec., or disabled (switch
selectable); tolerance: +50%, -0

Diagnostics:

V.52 compliant bit error rate pattern
(511/511E pattern) generator and
detector with error injection mode;
V.54 compliant—Local Analog Loopback
and Remote Digital Loopback, activated
by front panel switch or via RS-232
interface

Transformer Isolation:

2000 V RMS

Surge Protection:

Immune to IEC-801-5 Level 2, 1kV

Temperature:

-10°C to 70°C

Humidity:

100% condensing from -10°C to +30°C
Absolute humidity from +30°C to +70°C

Dimensions:

5.5” (W) X 7.5” (D) X 1.6” (H)
(13.9 cm X 19 cm X 4 cm)

Power Supply:

157-242 VAC Universal Interface