Fault codes – Pride Mobility Controller GC2 User Manual
Page 16

16
Basic Operation Instructions
GC2 Controller
www.pridemobility.com
FAULT CODES
The battery condition meter will flash fault codes when the controller system
detects an abnormal condition in the electrical system. All of the battery con-
dition meter LEDs will flash a number of times quickly, then pause, then flash
again. The battery condition meter will continue to flash the fault codes until
the problem is fixed. The table below identifies the individual fault codes. If
any of these fault codes persist, contact your authorized Pride Provider.
Fault
Codes
Probable Causes
Possible Solutions
1 Flash
The batteries need charging.
There is a bad connection to
the batteries.
Check the battery connections. If the
battery connections are good, then try
charging the batteries.
2 Flashes
There is a bad connection on
the left motor.
Check the left motor connections and
wiring harnesses.
3 Flashes
The left motor has a short to
the battery connection.
Contact your authorized Pride Pro-
vider.
4 Flashes
There is a bad connection on
the right motor.
Check the right motor connections
and wiring harnesses.
5 Flashes
The right motor has a short to a
battery connection.
Contact your authorized Pride Pro-
vider.
Scroll Left
to Right
The charge inhibit has been
activated.
Make sure that the battery charger is
not connected to the power base.
7 Flashes
There is a joystick fault.
Make sure the joystick is in the cen-
ter position and then power off and
on again.
8 Flashes
There is a control system fault.
Check power module and joystick
module connections and wiring.
9 Flashes
The park brakes have a bad
connection.
Check the left and right motor con-
nections and wiring.
10 Flashes
An excessive voltage has been
applied to the control system.
Check the battery connections.