beautypg.com

Fault codes, Fault probable cause(s) possible solution code – Pride Mobility INFMANU1773 User Manual

Page 16

background image

16

Basic Operation Instructions

Remote Plus Controller

www.pridemobility.com

Fault

Probable Cause(s)

Possible Solution

Code

1 Flash

The batteries need charging.

Check the battery connections. If the

There is a bad connection

battery connections are good, then

to the batteries.

try charging the batteries.

2 Flashes

There is a bad connection on

Check the left motor connections and

the left motor.

wiring harnesses.

3 Flashes

The left motor has a short to

Contact your authorized Pride

a battery connection.

Provider.

4 Flashes

There is a bad connection on

Check the right motor connections

the right motor.

and wiring harnesses.

5 Flashes

The right motor has a short to Contact your authorized Pride

a battery connection.

Provider.

6 Flashes

The charge inhibit has been

Make sure that the battery charger

activated.

is not connected to the power base.

7 Flashes

There is a joystick fault.

Make sure the joystick is in the center

position; power the unit off and then

on again.

8 Flashes

There is a control system fault. Check power module and joystick

module connections and wiring.

9 Flashes

The park brakes have a bad

Check the left and right motor

connection.

connections and wiring.

10 Flashes

An excessive voltage has

Check the battery connections.

been applied to the control

system.

FAULT CODES

The battery condition meter will flash fault codes when the controller system detects
an abnormal condition in the electrical system. All of the battery condition meter
LEDs will flash a number of times quickly, then pause, then flash again. The battery
condition meter will continue to flash the fault codes until the problem is fixed. The
following table identifies the individual fault codes. If you receive any of these fault