1. Perform the Contactor Test.

NOTE:Test

i s

c o d e

s p e c i f i c .

Codes above 10100 may

o r

m ay

n o t

h ave

a

Contactor PC Board.

2. The Contactor PC board or the

Control Board may be faulty.

Replace.

FUNCTION PROBLEMS (Continued)

Observe Safety Guidelines

detailed in the beginning of this manual.

Troubleshooting Guide –

See Wiring Diagrams for location of specified

components. See Wiring Diagrams for troubleshooting of specific circuits.

The gas solenoid valve will not

function.

1. M a ke

s u r e

t h e

L N - 2 5 ™

i s

equipped with a gas solenoid

valve and properly connected.

2. Make sure the gas supply is

adequate and the gas hoses

are not loose or kinked.

NOTE:Control Boards L12253-[ ]

or higher do not use a Gas

Solenoid PC Board.

1a.Pe r fo r m

t h e

Solenoid PC

Board and Gas Solenoid
Valve Test

NOTE:Test

i s

c o d e

s p e c i f i c .

Codes above 10100 may

o r

m ay

n o t

h ave

a

Solenoid PC Board.

2. If a K434-1 gas flow timer kit is

installed in the unit, disconnect

and plug in the timer jumper

p l u g .

I f

t h e

g a s

s o l e n o i d

f u n c t i o n s, t h e n r e p l a c e t h e

K434-1 kit.

3. The contactor board or remote

control board (if used) may be

faulty.

4. T h e c o n t r o l b o a r d m ay b e

faulty. Replace.

F-6

TROUBLESHOOTING AND REPAIR

F-6

LN-25™

PROBLEMS
(SYMPTOMS)

POSSIBLE AREAS OF
MISADJUSTMENT(S)

RECOMMENDED
COURSE OF ACTION

The wire feed motor r uns at a

constant speed with no control.

NOTE:Loss of tach feedback may

result in MAX speed or a

motor voltage of approx.

14VDC depending on the

Control Board being used.

1. M a ke s u r e t h e m o d e sw i t c h

(S3) is in the CV mode.

2. M a ke s u r e t h e w i r e s p e e d

c o n t r o l a n d t h e w i r e s p e e d

ra n g e

sw i t c h

( S 2 )

a r e

s e t

correctly.

1. Pe r fo r m

t h e

Hall

Effect

Module Test.

2. Perform the Wire Drive Motor

Test.

3. T h e c o n t r o l b o a r d m ay b e

faulty. Replace.

The contactor does not function.

1. Make cer tain the LN-25™ is

equipped with a contactor and

properly connected.

2. Check the connections to the

contactor PC board.

NOTE:Control Boards L12253-[ ]

o r h i g h e r d o n o t

u s e a

Contactor PC Board.

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,

contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.

Call 1-888-935-3877.