User manual – LevelOne ProCon GSW-2690 User Manual
Page 256
User Manual
Publication date: June, 2005
Revision A1
252
ACCESS
read-only
STATUS mandatory
DESCRIPTION
"Externel
loopback
test."
-- @@ACTION
ruby_diagnostic
::= { GSW2690Diagnostic 6 }
GSW2690PingTest OBJECT-TYPE
SYNTAX DisplayString
ACCESS
read-write
STATUS mandatory
DESCRIPTION
"Set the host address that you want to ping and the system will
return the test result."
-- @@ACTION
ruby_diagnostic
::= { GSW2690Diagnostic 7 }
----------------------------------------------------------------------------------------
GSW2690Log
OBJECT IDENTIFIER ::= { GSW2690Produces 7 }
GSW2690ClearLog OBJECT-TYPE
SYNTAX INTEGER(0|1)
ACCESS
read-write
STATUS mandatory
DESCRIPTION
"Clear
system
log.
Get this oid always return zero.
1 - clear log.
0 - do nothing. "
-- @@ACTION
ruby_log
::= { GSW2690Log 1 }
GSW2690UploadLog OBJECT-TYPE
SYNTAX INTEGER(0|1)
ACCESS
read-write
STATUS mandatory
DESCRIPTION
"Upload current system log. Set the correct tftp server first.
The format of log file is 'ModelName_SerialNumbuer_YYMMDD_HHMM'.
Get this oid always return zero.
1 - upload log
0 - do nothing. "
-- @@ACTION
ruby_log
::= { GSW2690Log 2 }
GSW2690AutoUploadLogState OBJECT-TYPE
SYNTAX INTEGER(0|1)
ACCESS
read-write
STATUS mandatory
DESCRIPTION
"Enable log auto-upload function. Set the correct tftp server first.
The format of log file is 'ModelName_SerialNumbuer_YYMMDD_HHMM'.