beautypg.com

User manual – LevelOne ProCon GSW-2690 User Manual

Page 256

background image

User Manual

Publication date: June, 2005
Revision A1

252

ACCESS

read-only

STATUS mandatory
DESCRIPTION
"Externel

loopback

test."

-- @@ACTION

ruby_diagnostic

::= { GSW2690Diagnostic 6 }


GSW2690PingTest OBJECT-TYPE

SYNTAX DisplayString

ACCESS

read-write

STATUS mandatory
DESCRIPTION

"Set the host address that you want to ping and the system will

return the test result."
-- @@ACTION

ruby_diagnostic

::= { GSW2690Diagnostic 7 }


----------------------------------------------------------------------------------------

GSW2690Log

OBJECT IDENTIFIER ::= { GSW2690Produces 7 }


GSW2690ClearLog OBJECT-TYPE

SYNTAX INTEGER(0|1)

ACCESS

read-write

STATUS mandatory
DESCRIPTION
"Clear

system

log.

Get this oid always return zero.
1 - clear log.
0 - do nothing. "
-- @@ACTION

ruby_log

::= { GSW2690Log 1 }


GSW2690UploadLog OBJECT-TYPE

SYNTAX INTEGER(0|1)

ACCESS

read-write

STATUS mandatory
DESCRIPTION

"Upload current system log. Set the correct tftp server first.

The format of log file is 'ModelName_SerialNumbuer_YYMMDD_HHMM'.
Get this oid always return zero.
1 - upload log
0 - do nothing. "
-- @@ACTION

ruby_log

::= { GSW2690Log 2 }


GSW2690AutoUploadLogState OBJECT-TYPE

SYNTAX INTEGER(0|1)

ACCESS

read-write

STATUS mandatory
DESCRIPTION

"Enable log auto-upload function. Set the correct tftp server first.

The format of log file is 'ModelName_SerialNumbuer_YYMMDD_HHMM'.