beautypg.com

User manual – LevelOne ProCon GSW-2690 User Manual

Page 21

background image

User Manual

Publication date: June, 2005

Revision A1

17

2-1-3-1. Configuring the Management Agent of 24 Fast Ethernet + 2 Gigabit L2

Managed Switch through the Serial RS-232 Port

To perform the configuration through RS-232 console port, the switch’s serial

port must be directly connected to a DCE device, for example, a PC, through
RS-232 cable with DB-9 connector. Next, run a terminal emulator with the default
setting of the switch’s serial port. With this, you can communicate with the switch.

In the switch, RS-232 interface only supports baud rate 57.6k bps with 8 data

bits, 1 stop bit, no parity check and no flow control.











To configure the switch, please follow the procedures below:

1.

Find the RS-232 DB-9 cable with female DB-9 connector bundled.
Normally, it just uses pins 2, 3 and 7. See also Appendix B for more
details on Null Modem Cable Specifications.

2.

Attaches the DB-9 female cable connector to the male serial RS-232
DB-9 connector on the switch.

3.

Attaches the other end of the serial RS-232 DB-9 cable to PC’s serial
port, running a terminal emulator supporting VT100/ANSI terminal with
The switch’s serial port default settings. For example,
Windows98

SE/2000/XP HyperTerminal utility.


Note: The switch’s serial port default settings are listed as follows:

Baud rate

57600

Stop

bits

1

Data bits

8

Parity

N

Flow

control

none

4.

When you complete the connection, then press key. The login
prompt will be shown on the screen. The default username and
password are shown as below:

Username = admin Password = admin

24 Fast Ethernet + 2 Gigabit L2
Managed Switch
Default IP Setting:
IP address = 192.168.1.1
Subnet Mask = 255.255.255.0
Default Gateway = 192.168.1.254

Terminal or Terminal Emulator

Fig. 2-6

RS-232 cable with female
DB-9 connector at both ends

RS-232

AC Line 100-240V 50/60 Hz

RS-232 DB-9 Connector