beautypg.com

Installation – Lincoln Electric POWER FEED IM584-D User Manual

Page 16

background image

A-8

INSTALLATION

POWER FEED 10

A-8

MSB - Most Significant Bit or Byte. This is the bit in a binary number or DIP switch bank that is furthest to the left.
LSB - Least Significant Bit or Byte. This is the bit in a binary number or DIP switch bank that is furthest to the right.

S2 DIP Switch Bank on Control Box Motherboard (For software version S24004-3 & up)

Switch

Off

On

1

Network Group ID, MSB (Assigns Control Box to a specific group) (Off is factory setting)

2

Network Group ID, LSB (Assigns Control Box to a specific group ) (Off is factory setting)

3

Spare

4

Spare

5

Spare

6

Must be off for normal operation

Adjust lower limits

7

Must be off for normal operation

Adjust upper limits

8

Must be on for European units only

Note: the factory shipped settings for all of the S1 and S2 switches is “OFF”.

S1 DIP Switch Bank on Control Box Motherboard (For software version S24004-2 only)

Switch

Off

On

1

US 4-Step Trigger Logic

Euro 4-Step Trigger Logic

2

WFS Display = inches/minute

WFS Display = meters/minute

3

Left Display is always preset WFS

Left Display is preset WFS when weld current is not flowing
Left Display is actual weld current when weld current is flowing

CC modes override this switch regardless of position. Left Display is always preset weld cur-
rent when weld current is not flowing and actual weld current when weld current is flowing

4

Run-in = Minimum Speed Available

Run-in = weld WFS

If any option containing a Run-in setting is connected to the motherboard, it automatically
overrides this switch regardless of position.

5

Spare

6

Acceleration, MSB (Sets acceleration rate for wire drive) see below

7

Acceleration (Sets acceleration rate for wire drive) see below

8

Acceleration, LSB (Sets acceleration rate for wire drive) see below