The following table lists the supported RDIMM population.

Table 11. Supported RDIMM population per channel

DIMM connectors
per channel

DIMMs installed in
each channel

DIMM type

DIMM speed

Ranks per DIMM
(any combination)

3

1

Registered DDR3
ECC

1066, 1333

Single-rank,
dual-rank

3

2

Registered DDR3
ECC

1066, 1333

Single-rank,
dual-rank

3

3

Registered DDR3
ECC

800

Single-rank,
dual-rank

3

1

Registered DDR3
ECC

1066

Quad-rank

3

2

Registered DDR3
ECC

800

Quad-rank

v

The following table lists the maximum DIMM population using ranked RDIMMs.

Table 12. Maximum memory population using ranked RDIMMs (depending on your model)

Number of RDIMMs

DIMM type

Size

Total memory

6

Single-rank RDIMMs

1 GB

6 GB

6

Single-rank RDIMMs

2 GB

12 GB

6

Dual-rank RDIMMs

2 GB

12 GB

4

Dual-rank RDIMMs

4 GB

16 GB

4

Quad-rank RDIMMs

4 GB

16 GB

6

Dual-rank RDIMMs

4 GB

24 GB

4

Quad-rank RDIMMs

8 GB (when available)

32 GB

v

The following table shows the RDIMM memory population rule to optimize the system performance.

Table 13. RDIMM population rule for dual-channel symmetric mode

DIMM connector
1

DIMM connector
2

DIMM connector
3

DIMM connector
4

DIMM connector
5

DIMM connector
6

Populated

Empty

Empty

Empty

Empty

Empty

Populated

Empty

Empty

Populated

Empty

Empty

Populated

Populated

Empty

Populated

Populated

Empty

Populated

Populated

Populated

Populated

Populated

Populated

Note:

The amount of usable memory is reduced, depending on the system configuration. A certain

amount of memory must be reserved for system resources. To view the total amount of installed
memory and the amount of configured memory, run the Setup utility.

Removing a memory module

To remove a DIMM, complete the following steps:
1.

Read the safety information in “Important Safety Information” on page 1 and “Guidelines for trained
service technicians” on page 115.

2.

Turn off the server and peripheral devices and disconnect the power cords and all external cables, if
necessary.

3.

Remove the cover (see “Removing and installing the cover” on page 119).

124