Roof attachment installation – Lochinvar TISUN SCH-I-O User Manual
Page 21

SCH Collectors Installation & Operation Manual
SCH Collectors Installation & Operation Manual
21
3
Roof Attachment Installation
(continued)
Install flange plate shingle (standard)
1. Determine roof type. Inspect the structural integrity of
the roof and the durability of the roof materials.
2. Determine the number of collectors needed for the
installation and the number of required roof attachments
from Table 3B or 3C on page 11.
3. Determine collector connection points (spacing).
Measure the spacing of the rafters or trusses to confirm
the dimensions and prepare for the system layout
(reference the Roof Attachment Spacing Section on
page
12).
4. Caulk (field supplied) around the perimeter of the flange
plate (FIG. 3-22).
5. Using the flange plate as a template, place the flange plate
on the roof and drill four (4) 6 mm holes as shown in
FIG. 3-23. Install the larger screws provided in the kit
into the 6mm holes securing the flange plate to the roof
(caulk around screws before tightening).
6. Install the four (4) remaining smaller screws in the
perimeter of the flange plate as shown in FIG. 3-23 (caulk
around screws before tightening).
7. Cover flange plate with roofing material, sealing it to the
roof (FIG. 3-24).
Figure 3-22 Caulk Around Perimeter of Flange Plate
CAULK AROUND
THE PERIMETER
OF THE FLANGE PLATE
~ Ø 5 mm
Figure 3-23 Drill Holes and Attach Flange Plate
COLLECTOR
SUBSTRUCTURE
HEX BOLT
SQUARE DISK
USE THE SMALLER SCREWS
IN THE PERIMETER OF THE
FLANGE PLATE
PRE-DRILL FOUR (4) 6MM
HOLES - USE THE LARGER
SCREWS TO SECURE THE
FLANGE PLATE
8. Slide the square disk onto the hex bolt (see FIG. 3-23).
9. Install the hex bolt with square disk attached into the
opening of the flange plate as shown in FIG. 3-23.
Note: Do not tighten hex bolt until ready to install on the
collector substructure.
10. Thread the hex nut (M8) and washer (M8) onto the bottom
of the hex bolt installed in Step 9.
11. Repeat Steps 4 - 10 until installation is complete.
Install hex bolt onto collector substructure (reference Section 4 -
Collector Installation)
Figure 3-24 Cover Flange Plate with Roofing Material
COVER FLANGE PLATE WITH
ROOFING MATERIAL, SEALING
IT TO THE ROOF
2”
4.7 mm
4.7”
6”
> 4.7”