beautypg.com

Lexicon Reverb/Effects Processor PCM96 User Manual

Page 30

background image

24

transmitting device is paused.

Mode - Select “Consumer” to send information in S/PDIF format.
Select “Professional” to send information in AES format.

Confidence Error - “0” indicates no problem. “1” indicates the PCM96
is detecting excessive jitter or noise on the digital audio line. No data
has been corrupted, but corrective action should be taken.

Sample Slip - An unchanging number indicates you are not slipping
samples. An increasing number indicates samples are misaligned with
the window defined by the Input Source. This may occur when an
external master changes sample rate, or when it is just powering up, but
should not occur in normal operation.

Bi-Phase Error - “0” indicates no problem. “1” indicates that at least
one bit (and therefore at least one audio sample) was corrupted.

CRC Error - “0” indicates no problem. “1” indicates a Cyclic
Redundancy Check error in the incoming data.

Parity Error - “0” indicates no problem. “1” indicates that at least one
bit (and therefore at least one audio sample) was corrupted.

MAchINe coNFIG

The Machine Config menu lets you configure the PCM96 processor as one,
two, three, or four virtual machines in a new preset. Note that once you’ve
selected a configuration, you must then populate each virtual machine with a
Machine Preset (see page 11 for more information).

Choices include:

Single Mono In Stereo Out
Single Stereo
Dual Mono
Cascade Stereo
Cascade Mono
Cascade Mono to Stereo
Combined Stereo Mono In

For more detailed descriptions of each configuration, see page 14.

MIdI coNtRoL

The MIDI Control sub-menu lets you adjust the following MIDI-related
options:

MIDI
Turns MIDI processing on or off.

Device ID
Select the connected MIDI device’s ID here. Choose from 0-126.

Base Channel
Select the connected MIDI device’s base channel here. Choose from 0-15.