2 thermal and atmospheric characteristics, 3 safety characteristics, Thermal and atmospheric characteristics – LSI SAS3041E User Manual
Page 43: Safety characteristics

Electrical and Environmental Specifications
3-19
Version 1.0
Copyright © 2006 by LSI Logic Corporation. All rights reserved.
3.2.2
Thermal and Atmospheric Characteristics
The atmospheric characteristics for the LSI PCIe to SAS host adapters
are:
•
Temperature range: 0 ˚C to 60 ˚C (dry bulb)
•
Relative humidity range: 5% to 90% non-condensing
•
Maximum dew point temperature: 32 ˚C
The following parameters define the storage and transit environment for
the LSI PCIe to SAS host adapters:
•
Temperature range:
−
45 ˚C to +105 ˚C (dry bulb)
•
Relative humidity range: 5% to 90% non-condensing
3.2.3
Safety Characteristics
All LSI PCIe to SAS host adapters meet or exceed the requirements of
UL flammability rating 94V-0. Each bare board is marked with the
supplier’s name or trademark, type, and UL flammability rating. Because
these boards are installed in a PCI Express bus slot, all voltages are
below the SELV 42.4 V limit.