beautypg.com

General information – Lennox Hearth ADAGIO-EN User Manual

Page 6

background image

6

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

General Information

The fireplace models covered in this manual

are direct-vent sealed combustion gas fireplace

heaters designed for residential application.

These direct-vent appliances operate with the

combustion chamber completely isolated from

the indoor environment.

All air for combustion is brought in from the

outside and exhaust gases are vented through

the same direct-vent, co-axial (intake/exhaust)

vent system.

The Millivolt appliances have a millivolt gas

control valve with piezo ignition system. If any

optional accessories that will require electrical

power are to be installed, the electrical power

must be provided at the time of appliance in-

stallation.

The Electronic appliances have an electronic

intermittent pilot ignition system. External

electrical pow-er is required to operate these

appliances.

These appliances comply with National Safety

Standards and are tested and listed by OMNI-Test

Laboratories, Inc. (Report No. 116-F-48-5) to

ANSI Z21.88 (in Canada, CSA-2.33), and CAN/

CGA-2.17-M91 in both USA and Canada, as

vented gas fireplace heaters.

The Installation must conform to local codes

or, in the absence of local codes, with the

National Fuel Gas Code, ANSI Z223.1/NFPA

54-latest edition, or the Natural Gas and Propane

Installation Code, CAN/CSA B149.1-latest edi-

tion. The appliance, when installed, must be

electrically grounded in accordance with local

codes or, in the absence of local codes, the

latest edition of the National Electrical Code,

ANSI/NFPA 70, or the Canadian Electrical Code,

CSA C22.1 - latest editions.

The vent termination is hot while in

operation and for a period of time fol-

lowing the use of the fireplace. Young

children should be carefully supervised

when they are in the same area as a

hot termination. To prevent contact with

hot surfaces, we recommend the use of

a termination guard. See Page 18 for

ordering information.

These fireplaces are designed as supple-

mental heaters. Therefore, it is advisable

to have an alternate primary heat source

when installed in a dwelling.

These appliances must not be connected to

a chimney or flue serving a separate solid

fuel burning appliance.

INSTALLATION, SERVICE,

AND MAINTENANCE

IMPORTANT: Improper installation,

adjustment, alteration, service, or

maintenance can cause injury or

property damage. Refer to this manual.

For assistance or additional information,

consult a qualified installer, service

agency or the gas supplier.
Only trim kit(s) supplied by the

manufacturer shall be used in the

installation of this appliance.
Draft relief openings must not be

covered or blocked.
These appliances must not be

connected to a chimney or flue serving a

separate solid fuel burning appliance.
Any change to this appliance and/or

its operating controls is dangerous.

Improper installation or use of this

appliance can cause serious injury or

death from fire, burns, explosion or

carbon monoxide poisoning.
Carbon Monoxide Poisoning:
Early

signs of carbon monoxide poisoning

are similar to the flu with headaches,

dizziness and/or nausea. If you

have these signs, obtain fresh air

immediately. Turn off the gas supply to

the appliance and have it serviced by

a qualified professional, as it may not

be operating correctly. Some people

are more affected by carbon monoxide

than others, including pregnant women,

people with heart or lung disease or

anemia, those under the influence of

alcohol, and those at high altitudes.
Turn off gas and electrical power to the

fireplace and allow it to cool before

cleaning or servicing the appliance.

OPERATION

Do not operate appliance with the glass

front removed, cracked, or broken.
These fireplaces are vented gas

appliances. Do not burn wood or other

material in these appliances.
This appliance is only for use with the

type of gas indicated on rating plate.

This appliance is not convertible for use

with other gases, unless a certified kit is

used.

These appliances are designed to

operate on natural gas or propane

gas only. The use of other fuels or

combinations of fuels will degrade the

performance of this system and may be

dangerous.
Provide adequate clearances around

air openings and adequate accessibility

clearance for service and proper

operation. Never obstruct the front

openings of the appliance.
Do not use this appliance if any part has

been under water. Immediately call a

qualified service technician to inspect the

appliance and to replace any part of the

control system and any gas control that

has been under water.

WARRANTY

Failure to comply with the installation

and operating instructions provided

will result in an improperly installed

and operating appliance, voiding its

warranty.
Do not attempt to alter or modify the

construction of the appliance or its

components. Any modification or

alteration may void the warranty,

certification, and listings of this unit.