Lennox Hearth BRENTWOOD LV User Manual
Page 27
Fireplace Model Brentwood™ LV - Approved Venting Components
manufactured by Security Chimneys International™ only.
• 6” diameter chimney - AC (air cooled), Secure Temp
®
ASHT (or
Nova Temp
®
HT6103+) and Secure Temp S-2100+ (or Nova Temp
HT6000+).
• 6” diameter chimney for relining masonry chimneys - Tubinox™
chimney (or Projet
®
SS), 6” diameter with adaptor for installation in
a masonry chimney.
Secure Temp ASHT 1” High Temp. Insulated Stainless Steel Chimney
6” I.D and 8” O.D., Double-Wall Stainl. Steel, Listed to CAN/UCL-S604 and UL-103HT
Description
Part/Cat. No.
Lengths and Misc. Chimney Components
8” length, 6” Dia., 6L8
6L8
12” length, 6” Dia., 6L12
6L12
18” length, 6” Dia., 6L18
6L18
24” length, 6” Dia., 6L24
6L24
36” length, 6” Dia., 6L36
6L36
48” length, 6” Dia., 6L48
6L48
Adjustable Length 12”, 6” Dia., 6LA
6LA
15º elbow, 6” Dia., 6E15
6E15
30º elbow, 6” Dia., 6E30
6E30
Rain Termination Cap, 6” Dia., 6CC
6CC
Spark Arrester Screen (universal spark arrester band), PE
PE
Wall Band, BM
BM
Supports
Offset Support, SO
SO
Roof Support, ST
ST
Roof Brace, BS2
BS2
Firestops
Firestop, 6BF
6BF
Radiation Shield, 6RS
6RS
Insulated Attic Radiation Shield, 6RSA
6RSA2
Insulated Wall Radiation Shield, 6RSM
6RSM
Insulated Wall Radiation Shield, 30º, 6RSMI30
6RSMI30
Uninsulated Wall Radiation Shield, 30º, 6RSM30
6RSM30
Attic Radiation Shield
H0487
Roof Flashings
Flat Roof Flashing, 6FR
6FR
1/12 - 7/12 (5º - 30º), 6FAR
6FAR
8/12 - 12/12 (30º - 45º), 6FBR
6FBR
Storm Collar, 6FC
6FC
NOTES:
j
Nova Temp
HT6000+ is equivalent to Secure Temp
S-2100+
k
Nova Temp
HT6103+ is equivalent to Secure Temp
ASHT
l
This appliance is equipped with the ASHT Chimney Adaptor. When other
chimney is used, a chimney adaptor for that chimney will be required.
m
Chimney Adaptor (S-2100+ / HT6000+) for CANADA ONLY - If you want to
install a S-2100+ / HT6000+ chimney, an adaptor is available (6UCA).
n
AC Chimney is NOT recommended at elevations above 4,000 feet or in cold
climates (climates where temperatures will fall below 32° F / 0° C). When
using AC chimney, an AC6SB starter section must be used before installing
an elbow. When an offset is needed immediately off the top of the fireplace,
an elbow starter section, AC6SB30 (H3780), is available.
SECURITY CHIMNEYS™ - PARTS AND COMPONENTS LISTS
The components listed below must be ordered from Security Chimneys International™. Contact your Security Chimneys Distributor or Dealer for ordering
information.
Security Chimneys International Limited
2125 Monterey, Laval, Quebec
Canada, H7L 3T6
www.securitychimneys.com
450-973-9999
1-800-361-4909 (USA)
1-800-667-3387 (Canada)
27