CHIMNEY SUPPORT INSTALLATION

Universal Roof Support

*

When installing a support, slightly lift the chimney system so the weight

will lie on the support, not on the fireplace to reduce expansion noises.

This support has three possible uses:

1. For ASHT / HT6103+ and S-2100+ / HT6000+, it must be used on a

roof to support the chimney

*

.

2. It may be used on a floor, ceiling or roof above an offset to support

the chimney above the offset.

3. It may be used on a floor, ceiling or roof as a supplementary sup-

port.

Table 6 gives maximum height of supported chimney.

NOTE: For the AC chimney

*

, a support section must be used every 40

feet (12 m) instead of the universal roof support (ST

*

).

For roof support installation, refer to the instructions provided with the

support.

Universal Offset Support

*

This support is used to support the chimney above an offset. When

the chimney offset is used to traverse a wall this support may be used

on the wall to support the chimney. The maximum heights are given in

Table 6. For offset support installation, refer to the instructions provided

with the support.

CHIMNEY MODEL

*

MAXIMUM HEIGHT OF

SUPPORTED CHIMNEY

OFFSET SUPPORT

ROOF SUPPORT

ASHT / HT6103+ (6” dia).

28 feet (8.54 m)

29 feet (8.84 m)

S-2100+ / HT6000+ (6” dia).

18 feet (5.49 m)

20 feet (6.1 m)

AC (6” dia).

40 feet (12.19 m)

50 feet (15.20 m)

Table 6

CHIMNEY CHASE AND MULTIPLE TERMINATIONS

For the purpose of this manual, a chimney chase is considered a part of

the chimney system rather than part of a building. The termination must

be placed a minimum of 18” (460 mm) above the chase.

For installations where more than one chimney is located in the same

chase or within the same area, we suggest that their terminations be

separated by at least 16” (410 mm) horizontally, and 18” (460 mm) verti-

cally. This separation is to prevent smoke migrating from one chimney

to another (see Figure 37).

CHIMNEY ADAPTOR

*

(S-2100+ / HT6000+) CANADA ONLY

The fireplace is normally supplied with a chimney adaptor suitable for the

ASHT / HT6103+ chimney

*

. If you want to install a S-2100+ / HT6000+

chimney, an adaptor is available (6UCA

*

) (Figure 38). A separate starter

section will also be required if AC chimney

*

is installed.

Figure 38

Chimney Adaptor

*

-

Canada only

18” (460 mm)

16” (410 mm)

18” (460 mm)

18” (460 mm)

16” (410 mm)

Figure 37

*

Available from Security Chimneys™

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.