HOT AIR DUCTING INSTALLATION

Different hot air ducting systems can be installed

with the Brentwood™ LV fireplace:

- Gravity kit

- Forced air kit

Gravity Kit

The gravity kit is designed for double hot air

outlets and includes: (See Figures 20 and 21)

- 2 telescopic lengths 8” I.D.

- 2 90º elbows 8” I.D.

- 2 hot air outlet kits (grill and frames)

- 2 adaptors

See Gravity Kit Accessories on Page 24.
The only blower that can be used with the gravity

kit is the UZY6.
The gravity kit must be used with the clean face

kit to allow hot air flow that would normally

come out of the top louver. To do so, follow

the steps below:

a) Install the clean face kit making sure that

the insulation strip is installed inside.

b) The fireplace façade can be covered with

non-combustible material (Figure 22).

For safe installation, the gravity kit must meet

the following requirements:
Minimum height* 68” (1,727 mm)

Maximum length

See Figures 20 and 21

* The height of the louver must be measured

from the base of the Brentwood LV fireplace to

the middle point of the louver.
To extend the double outlet system forward

of the Brentwood LV fireplace (not flush), it

will be necessary to purchase two adjustable

lengths (H8951).
When installing the double outlet system, the

hot air outlets can be installed in the same room

as the fireplace, or one or both of the outlets

can be installed in adjacent or upper rooms.

Installing the ducts at different elevations will

tend to exhaust more heat out of the higher

outlet (Figure 21).

Frame

Grill

Figure 20

WARNING: Both pipes of

the double hot air outlet

must be installed. Any oth-

er installation may cause

fire and void warranty.

6-1/2” Min.

(to ceiling)

Figure 21

Figure 22

Flashing

Collar

Rain Cap

Roof Support

Attic Radiation

Shield

Radiation Shield (Firestop)

Non-Combustible

Facing

Maintain at least 6-1/2”

(160 mm) clearance from

the outlet grill framing to

a combustible ceiling,

side wall or mantel.

Outlet Grill

Outlet Grill

WARNING: The outlet grills

should not be installed fac-

ing upward through a floor.

Danger of burns can result

if grills in floor are stepped

on.

10’

(3.1m)

Max.

13” x 13”

(330mm x 330mm)

10’ (3.1m)

Max.

68” Min.

(1727mm)

45” Min.

(1143mm)

u

u

Combustibles are not allowed below top

spacers above the fireplace. Facing in front

of fireplace must be non-combustible below

this area.

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

14