Tunnel – modem emulation page – Lantronix Data Center-Grade Evolution Device Server EDS32PR User Manual
Page 65

7: Network, Serial Line, and Tunnel Settings
EDS Device Servers User Guide
65
Tunnel – Packing Mode Page
Tunnel – Packing
Mode Page
Settings
Description
Mode
Select the method used to pack data. Choices are:
Disabled = data is never packed. (default)
Timeout = data is sent after the timeout elapses.
Send Character = data is sent when the send character is read on
the serial line.
Timeout
Enter the maximum number of milliseconds to wait before sending
queued data across the network. Default is 1000 milliseconds.
Threshold
Enter the queued data limit that, when reached, immediately sends
queued data to the network. Default is 512 bytes.
Send Character
Enter the send character. When this character is read on the serial
line, it forces the queued data to be sent immediately. Default is
Trailing Character
Enter the trailing character. This character is inserted into the
outgoing data stream immediately after the send character. Default is
Tunnel – Modem Emulation Page
A tunnel in connect mode can be initiated using modem commands incoming from the
serial line. If you click Modem Emulation at the top of one of the Tunnel pages, the
Tunnel – Modem Emulation page displays. Here you can select modem emulation
settings for the tunnel selected at the top of the page. For more information about modem
emulation, see
on page