beautypg.com

Tunnel – connect mode, Tunnel – connect mode page – Lantronix Data Center-Grade Evolution Device Server EDS32PR User Manual

Page 59

background image

7: Network, Serial Line, and Tunnel Settings

EDS Device Servers User Guide

59

Tunnel –
Accept Mode
Page Settings

Description

Email on Connect

Select whether an email is sent when a connection is made.

None = do not send an email.

Email # = send an email corresponding to the tunnel number.

Email on
Disconnect

Select whether an email corresponding to the tunnel number is sent
when a connection is closed.

None = do not send an email.

Email # = send an email corresponding to the tunnel number.

Password

Enter a password that clients must send to the EDS within 30 seconds
from opening a network connection to enable data transmission.

The password can have up to 31 characters and must contain only
alphanumeric characters and punctuation. When set, the password sent
to the EDS must be terminated with one of the following: (a) 0x10 (LF),
(b) 0x00, (c) 0x13 0x10 (CR LF), or (d) 0x13 0x00.

Prompt for
Password

Indicate whether the user should be prompted for the password upon
connection.

On = prompt for a password upon connection.

Off = do not prompt for a password upon connection.

Tunnel – Connect Mode Page

Connect Mode determines how the EDS initiates a connection to a remote host or device.
If you click Connect Mode at the top of one of the Tunnel pages, the Tunnel – Connect
Mode page displays. Here you can select the method for starting a tunnel in Connect
mode and select other settings for the tunnel selected at the top of the page.

Any configuration changes you make on the displayed page apply to the tunnel you
selected at the top of this page. For example, if Tunnel 1 is selected, any configuration
changes you make apply to tunnel 1.

Under Current Configuration, both Remote Address and Remote Port have a Delete
link that lets you delete the remote address and port number shown. If you click this link,
a message tells you that your action may stop an active connection. Click OK to proceed
or Cancel to cancel the operation.

For more information about Connect mode, see

Connect Mode

on page

145

.