Installation, Technical specifications – power mig, 215xt – Lincoln Electric POWER MIG 11521 User Manual
Page 10
INSTALLATION
A-2
A-2
Power MIG® 215XT
75°C Copper Wire
75°C Copper Wire
Input Ampere
in Conduit
in Conduit
Input Voltage/
Fuse or Breaker
Rating On
AWG (IEC) Sizes
AWG (IEC) Sizes
Frequency (Hz)
Size (Super Lag)
Nameplate
(For lengths
(For lengths
up to 100 ft.)
exceeding 100 ft.)
208/50/60
60
45A
10 (6 mm2)
8 (10 mm2)
230/50/60
60
41A
10 (6 mm2)
8 (10 mm2)
NOTE: Use #10 AWG Grounding Wire
TECHNICAL SPECIFICATIONS – POWER MIG
®
215XT
INPUT – SINGLE PHASE ONLY
RATED OUTPUT
OUTPUT
RECOMMENDED INPUT WIRE AND FUSE SIZES
Height
Width
Depth
Weight
31.79 in
18.88 in
38.78 in
210 Ibs
808 mm
480 mm
985 mm
95 kg
PHYSICAL DIMENSIONS
Wire Speed
50 – 700 IPM (1.27 – 17.8 m/minute)
WIRE SPEED RANGE
Standard Voltage/Phase/Frequency
Input Current @ 170 Amp Rated Output Input Current @ 215 Amp Rated Output
208/230/1/50/60 Hz
(With 115V receptacle loaded to 15A)
(With 115V receptacle loaded to 15A)
39/35 Amps
45/41 Amps
TEMPERATURE RANGES
STORAGE TEMPERATURE RANGE
-40°F to 185°F(-40°C to +40°C)
OPERATING TEMPERATURE RANGE
-4°F to 104°F(-20°C to +40°C)
Duty Cycle
Amps
Volts at Rated Amperes
30%
215 Amps
22 Volts
40%
190 Amps
23 Volts
60%
170 Amps
24 Volts
Welding Current Range
Maximum Open Circuit Voltage
Welding Voltage Range
30 – 250Amps
35 Volts
13.5-24 Volts