Lennox Hearth LEGACY S260 T-TOP User Manual
Page 7
7
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Figure 2 - Top View, Parallel Installation
Figure 3 - Side View, Alcove and Parallel
Installations
Footnotes:
1- These dimensions to the stove body are for reference only. Actual distances should be measured from the stove’s flue collar.
2- Minimum noncombustible hearth pad dimensions.
3- Shield shall be attached to the rear of the stove pipe with a 1” air space and must run from the top of the stove to the ceiling.
4- Not applicable to alcove installations.
5- In corner applications, when installed at minimum back wall clearances, the required floor protection is dimensioned off the back plane of the stove, therefore the
floor protection required off the back corners (at a 45 degree angle) only needs to extend to the wall. This situation will only occur in CANADA installations.
6- Reference dimension only, to assist in planning the installation.
Clearances to connector pipe shall be measured from the flue collar of the stove.
PIPE
INSTALLATION
A
B (1)
C
D (1)
E†
F (1,4)
G (4)
H (2)
6” Single Wall
Residential
18”
(450mm)
15-1/2”
(394mm)
26”
(660mm)
16”
(406mm)
8”
200mm
11”
(279mm)
21”
(533mm)
USA-37-1/4”
CAN-1200mm
6” Double Wall Residential or Alcove
or Mobile Home*
12”
(305mm)
9-1/2"
(241mm)
23”
(584mm)
13”
(330mm)
8”
200mm
11”
(279mm)
21”
(533mm)
USA-37-1/4”
CAN-1200mm
8” Single Wall
Residential
23”
(584mm)
20-1/2”
(521mm)
28”
(711mm)
18”
(450mm)
8”
200mm
13”
(330mm)
23”
(584mm)
USA-37-1/4”
CAN-1200mm
8” Double Wall Residential or
Mobile Home*
16”
(406mm)
13-1/2”
(343mm)
25”
(635mm)
15”
(381mm)
8”
200mm
12”
(305mm)
22”
(559mm)
USA-37-1/4”
CAN-1200mm
8” Double Wall Alcove - Residential
or Mobile Home*
16”
(406mm)
28”
(711mm)
28”
(711mm)
18”
(450mm)
8”
200mm
N/A
N/A
USA-37-1/4”
CAN-1200mm
PIPE
INSTALLATION
I (6)
J (2)
K
L (5)
M
T (6)
6” Single Wall
Residential
USA-52-3/4”
CAN-1391mm
USA-37-1/2”
CAN-1118mm
USA-16”
CAN-450mm
USA-0”
CAN-200mm
N/A
USA-66”
CAN-1727mm
6” Double Wall
Residential or Alcove
or Mobile Home*
USA-46-3/4”
CAN-1238mm
USA-37-1/2”
CAN-1118mm
USA-16”
CAN-450mm
USA-0”
CAN-200mm
84” 2134MM
USA-66”
CAN-1727mm
8” Single Wall
Residential
USA-57-3/4”
CAN-1518mm
USA-37-1/2”
CAN-1118mm
USA-16”
CAN-450mm
USA-0”
CAN-200mm
N/A
USA-68-3/4”
CAN-1797mm
8” Double Wall
Residential or
Mobile Home*
USA-50-3/4”
CAN-1340mm
USA-37-1/2”
CAN-1118mm
USA-16”
CAN-450mm
USA-0”
CAN-200mm
N/A
USA-67-1/4”
CAN-1759mm
8” Double Wall
Alcove - Residential
or Mobile Home*
USA-50-3/4”
CAN-1340mm
USA-37-1/2”
CAN-1118mm
USA-16”
CAN-450mm
USA-0”
CAN-200mm
84” 2134MM
USA-67-1/4”
CAN-1759mm
† USA=8" (200mm) from door opening, Canada=8" (200 mm) from sides and back of unit
u
Dimensions to Stove Body
* Mobile Home - USA only
Clearances may only be reduced by means approved by the regulatory authority.
L
C
D
†E
†E
K
Floor Protector
H
I
J
B
A
M
96” Min.
I
Floor Protection
K
T
J
H
Floor
Protection
F
F
G
G
Figure 4 - Top View Corner Clearance,
Stove and Flue to Wall
48”
Max.
Depth
8” Ø
Flue Collar
INSTALLATION CLEARANCES - REFER TO FIGURES 2, 3 AND 4