Factory default settings, Channel 1 configuration defaults, Expert settings defaults – Lantronix UDS100 User Manual
Page 38: Security settings defaults, Exit configuration mode

Configuring the UDS Using Telnet or the Serial Port
UDS10/UDS100 User Guide
38
Factory Default Settings
Select 7 to reset the unit’s serial port to the factory default settings. The server
configurations (IP address information) remain unchanged. The specific settings that
this option changes are in the following list:
Channel 1 Configuration Defaults
Baudrate 9600
I/F Mode
4C (1 stop bit, no parity, 8 bit, RS-232C)
Own TCP port number
10001
Connect Mode
C0 (always accept incoming connection; no active
connection startup)
Hostlist retry counter
3
Hostlist retry timeout
250 (msec)
Start character
0x0D (CR)
All other settings
0
Expert Settings Defaults
TCP keepalive
45 (seconds)
ARP cache timeout
600 (seconds)
Security Settings Defaults
SNMP Enabled
SNMP community name
public
Telnet setup
Enabled
TFTP download
Enabled
Port 77FEh
Enabled
Web Server
Enabled
ECHO Disabled
Encryption Disabled
Enhanced password
Disabled
Exit Configuration Mode
To exit Setup Mode:
To save all changes and reboot, select 9. All values are stored in nonvolatile
memory.
To exit the configuration mode without saving changes or rebooting, select 8.