beautypg.com

Caution, Operator setup (continued) – Linear LRA User Manual

Page 8

background image

LRA Linear Residential Actuator Installation Guide

- 6 -

228158 Revision X13 2-3-2009

Operator Setup (Continued)

Limit Switch Adjustment

The open and close limit switches are adjustable by sliding
them on the operator’s frame . Sliding either switch closer to
the center of the operator

decreases the gate travel .

To limit the

1.

opening travel of the gate for setup, loosen the locking

screw on the open limit switch, slide the switch towards the center of
the operator (see Figure 8).
With the gate closed, apply power to the Controller,

2.

STAY CLEAR

OF THE GATE and press the OPEN button.
Observe the gate as it opens, and watch the point where it stops.

3.

To limit the

4.

closing travel of the gate for setup, loosen the locking

screw on the close limit switch, remove the wire holding plugs from
the wire slot in the channel, slide the switch towards the center of the
operator (see Figure 9).
Be sure to

5.

STAY CLEAR OF THE GATE and press the CLOSE

button.
Observe the gate as it closes, and watch the point where it stops.

6.

Adjust the two limit switches until the open and close stopping points

7.

are set correctly for the gate.

TIGHTEN THE LOCKING SCREWS

ON THE LIMIT SWITCHES.

Push any extra limit wire back into the motor housing. Replace the

8.

limit switch wire holding plugs to retain the limit switch wire.

Manual Disconnect

In case of a power failure or other condition, the gate can be manually
moved without action from the operator by using the manual disconnect
switch (see Figure 11).
To activate the manual disconnect switch:

Open the cover on the switch.

1.

Insert the disconnect key (supplied with operator).

2.

Turn the key clockwise 90˚.

3.

Reverse the steps to re-engage the operator.

4.

SLIDE OPEN LIMIT SWITCH

TO ADJUST OPEN LIMIT

LIMIT SWITCH LOCKING SCREW

OPEN LIMIT SWITCH

Figure 8. Open Limit Switch

Figure 9. Close Limit Switch

SLIDE CLOSE LIMIT SWITCH
TO ADJUST CLOSE LIMIT

LIMIT SWITCH
LOCKING SCREW

CLOSE LIMIT SWITCH

REMOVE AND REPLACE

LIMIT WIRE PLUG DURING

LIMIT SWITCH ADJUSTMENT

CAUTION

Be careful not to damage the limit switch wires while adjusting

the limit switches. Gently pull the limit switch wire while

tightening the limit switch locking screw (see Figure 10).

DISCONNECT
(UNLOCK)

CONNECT
(LOCK)

MANUAL DISCONNECT
CAN BE USED TO

DISENGAGE
OPERATOR

Figure 11. Manual Disconnect

AVOID PINCHING THE LIMIT SWITCH
WIRE BY GENTLY PULLING IT WHILE
TIGHTENING THE LIMIT SWITCH

Figure 10. Limit Switch Wire