See table f.4, Amphenol resistance test, Troubleshooting & repair – Lincoln Electric VANTAGE 400 User Manual
Page 129: Remote receptacle resistance test (continued)
TROUBLESHOOTING & REPAIR
F-81
F-81
VANTAGE® 400
REMOTE RECEPTACLE RESISTANCE TEST (continued)
TABLE - F.4
N/A
PIN “G” (#75B) to PIN “Å” (#32)
500K or Higher
N/A
PIN “G” (#75B) to PIN “B” (GND-A)
500K or Higher
N/A
PIN “G” (#75B) to PIN “C” (#2B)
500K or Higher
N/A
PIN “G” (#75B) to PIN “D” (#4B)
500K or Higher
N/A
PIN “G” (#75B) to PIN “E” (#77B)
500K or Higher
N/A
PIN “G” (#75B) to PIN “F” (#76B)
500K or Higher
N/A
PIN “G” (#75B) to PIN “H” (#21)
500K or Higher
N/A
PIN “G” (#75B) to PIN “I” (#41A)
500K or Higher
N/A
PIN “G” (#75B) to PIN “J” (#31)
500K or Higher
N/A
PIN “G” (#75B) to PIN “K” (#42A)
500K or Higher
N/A
PIN “F” (#76B) to PIN “A” (#42)
500K or Higher
N/A
PIN “F” (#76B) to PIN “B” (GND-A)
500K or Higher
N/A
PIN “F” (#76B) to PIN “C” (#2B)
500K or Higher
N/A
PIN “F” (#76B) to PIN “D” (#4B)
500K or Higher
N/A
PIN “F” (#76B) to PIN “E” (#77B)
500K or Higher
N/A
PIN “F” (#76B) to PIN “H” (21)
500K or Higher
N/A
PIN “F” (#76B) to PIN “I” (#41A)
500K or Higher
N/A
PIN “F” (#76B) to PIN “J” (#31)
500K or Higher
N/A
PIN “F” (#76B) to PIN “K” (#42A)
500K or Higher
N/A
PIN “E” (#77B) to PIN “A” (#32)
500K or Higher
N/A
PIN “E” (#77B) to PIN “B” (GND-2)
500K or Higher
N/A
PIN “E” (#77B) to PIN “C” (#2B)
500K or Higher
N/A
PIN “E” (#77B) to PIN “D” (#4B)
500K or Higher
N/A
PIN “E” (#77B) to PIN “H” (#21)
500K or Higher
N/A
PIN “E” (#77B) to PIN “I” (#41A)
500K or Higher
N/A
PIN “E” (#77B) to PIN “J” (#31)
500K or Higher
N/A
PIN “E” (#77B) to PIN “K” (42A)
500K or Higher
REMOTELY CONTROLLED
PIN “C” (#2B) to PIN “D” (#4B)
500K or Higher
WELD TERMINALS ON
PIN “C” (#2B) to PIN “D” (#4B)
*
WELDING TERMINAL
SWITCH SETTING
OHMMETER
CONNECTION
OHMMETER READING
AMPHENOL RESISTANCE TEST
*
Resistance should be very low, The Ohmmeter should read about the same value as one would get by
touching the two meter probes together.