beautypg.com

Troubleshooting, Caution – Lincoln Electric IDEALARC CV-400-I User Manual

Page 25

background image

E-5

TROUBLESHOOTING

E-5

CV-400-I

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your

Local Lincoln Authorized Field Service Facility

for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENTS(S)

RECOMMENDED

COURSE OF ACTION

Output Control not functioning on the
machine.

Poor arc striking with semiautomatic
wire feeders.

Poor arc characteristics

1. Local/Remote switch is in

the "Remote" position.

2. Faulty Voltage Adjust

potentiometer.

3. Leads or connections open in

control circuit.

4. Malfunctioning Remote Control.

5. Faulty Control PC board.

1. Poor work connection.

2. Improper procedures.

3. Wire feed acceleration too fast or

too slow.

4. Defective PC Board.

1. Control PC Board defective.

1. Move switch toggle to the "Local"

position.

2. Check and replace if found faulty.

3. Check lead continuity and connec-

tions for an open and repair if neces-
sary.

4. See "Options Troubleshooting".

5. See PC Board Troubleshooting

Procedure.

1. Work connection must be adequate

for application.

2. Adjust procedures for improved start-

ing.

3. Adjust wire feeder acceleration set-

ting, if provided.

4. See PC Board Troubleshooting

Procedure.

1. See PC Board Troubleshooting

Procedure.