Troubleshooting and repair, Input contactor test procedure (continued) – Lincoln Electric INVERTEC SVM199-A User Manual
Page 66

INPUT CONTACTOR TEST PROCEDURE (continued)
PROCEDURE
1. Remove input power to the INVERTEC®
V450-PRO.
2. Using the 3/8” nut driver, remove the input
access panel and case top.
3. Locate, mark, and remove the two leads (601,
X4) that are connected to the input contactor
coil. See Figure F.4.
4. Using the external 24 VAC supply, apply 24
VAC to the terminals of the input contactor coil.
If the contactor does NOT activate, the input
contactor is faulty. Replace.
TROUBLESHOOTING AND REPAIR
F-26
F-26
INVERTEC® V450-PRO
INPUT
CONTACTOR
601
X4
INPUT
CONTACTOR
601
X4
FIGURE F.4 – INPUT CONTACTOR COIL
See also other documents in the category Lincoln Electric Tools:
- AIR VANTAGE IM10065 (54 pages)
- PRECISION TIG IM936 (44 pages)
- MAGNUM IM887 (20 pages)
- X-Tractor 1GC (4 pages)
- CAN-M393 (3 pages)
- CV ADAPTER IM309-D (46 pages)
- Idealarc 250 (2 pages)
- L12810-1 (4 pages)
- IM359-G (34 pages)
- OUTBACK 145 (34 pages)
- 4.1 (20 pages)
- CV-655 (47 pages)
- K1308-12 (4 pages)
- IM803-B (31 pages)
- LN-25 IM10092 (39 pages)
- PRECISION TIG 275 IM702-A (46 pages)
- Pipeliner 200D (4 pages)
- POWER FEED 10M SINGLE/DUAL SVM172-A (151 pages)
- CLASSIC 300G IM659-B (33 pages)
- INVERTEC V350-PRO IM708 (38 pages)
- Magnum 300 and 400 GMA Gun & Cable Assemblies K514 (29 pages)
- CLASSIC III 10061 (34 pages)
- 347 AC-DC (3 pages)
- INVERTEC IM958 (38 pages)
- Cool-Arc 40 (2 pages)
- IM795 (39 pages)
- Excalibur 11018M MR (1 page)
- METALUX 396T8HO (2 pages)
- MIG PAK HD IM822 (39 pages)
- VINTAGE 400 (CE) IM889-A (49 pages)
- IM481-B (35 pages)
- POWER MIG SVM157-A (91 pages)
- 600-I (2 pages)
- 4R90 (8 pages)
- IM613-B (54 pages)
- pmn (35 pages)
- RANGER 250 IM919 (49 pages)
- Welding Helmet (4 pages)
- IM355-C LN-9F GMA (70 pages)
- IM628 (17 pages)
- COOL ARC 35 IM959 (22 pages)
- POWER MIG 215 (35 pages)
- LN-25 PRO IM901-A (44 pages)
- METALUX 248 (2 pages)
- MAGNUM PCT125 (25 pages)