Please read before proceeding
Installer – Read all instructions,
including this manual and the
EnergyRite Installation and Operation
Manual, before installing. Perform steps
in the order given.
User – This manual is for use only by a
qualified heating installer/service
technician. Refer to the EnergyRite
User’s Information Manual for your
reference.
Have this pool heater serviced/inspected
by a qualified service technician at least
annually.
Failure to comply with the above could
result in severe personal injury, death or
substantial property damage.
When calling or writing about the pool
heater – Please have the pool heater model
and serial number from the pool heater
rating plate.
Consider piping and installation when
determining pool heater location (see the
EnergyRite Installation and Operation
Manual).
Any claims for damage or shortage in
shipment must be filed immediately against
the transportation company by the
consignee.
Service Manual
3
Handling ceramic fiber materials
REMOVAL OF COMBUSTION CHAMBER LINING
The combustion chamber insulation in this product contains ceramic fiber material. Ceramic fibers can be
converted to cristobalite in very high temperature applications. The International Agency for Research on
Cancer (IARC) has concluded, “Crystalline silica inhaled in the form of quartz or cristobalite from
occupational sources is carcinogenic to humans (Group 1).”:
Avoid breathing dust and contact with skin and eyes.
• Use NIOSH certified dust respirator (N95). This type of respirator is based on the OSHA
requirements for cristobalite at the time this document was written. Other types of respirators may
be needed depending on the job site conditions. Current NIOSH recommendations can be found on
the NIOSH website at http://www.cdc.gov/niosh/homepage.html. NIOSH approved respirators,
manufacturers, and phone numbers are also listed on this website.
• Wear long-sleeved, loose fitting clothing, gloves, and eye protection.
Apply enough water to the combustion chamber lining to prevent airborne dust.
Remove the combustion chamber lining from the pool heater and place it in a plastic bag for disposal.
Wash potentially contaminated clothes separately from other clothing. Rinse clothes washer
thoroughly.
NIOSH stated First Aid.
Eye: Irrigate immediately.
Breathing: Fresh air.
ƽ WARNING
NOTICE
ƽ WARNING