beautypg.com

Maintenance, Maintenance and annual startup, Service technician – Lochinvar EnergyRite ER152 User Manual

Page 13: Owner maintenance

background image

2

Maintenance

Service Manual

13

Maintenance and annual startup

Table 2A Service and Maintenance Schedules

Service technician

(see the following pages for instructions)

General:

• Address reported problems

• Inspect interior; clean and vacuum if

necessary

• Check for leaks (water, gas, and flue)

• Verify flue and air lines in good

condition and sealed tight

• Check control settings per the Access

Setup Menu section of this manual

• Check ignition and flame sense

electrodes (sand off any deposits;
clean and reposition)

• Check wiring and connections

• Perform start-up checkout and

performance verification per Section 9
in the EnergyRite Installation and
Operation Manual

• Flame inspection (stable, uniform)

If combustion or performance
indicate need:

• Clean burners

• Clean heat exchanger

ANNUAL

ST

ART

-UP

Owner maintenance

(see the EnergyRite User’s Information Manual for

instructions)

Daily

• Check pool heater area

Monthly

• Check vent piping

• Check air inlet piping (if

applicable)

• Check relief valve (if applicable)

Periodically

• Test low water cutoff (if used)

• Reset button (low water cutoff)

Every

6 months

• Check pool heater piping (gas

and water) for leaks

• Operate relief valve (if

applicable)

End

of season

• Shut the pool heater down and

winterize if location is subjected
to freezing temperatures, see the
Winterizing section on page 21 of
this manual

This manual is related to the following products: