LINDY CPU Switch Dual Junior Installation and Use
Page 16
When cascading LINDY CPU Switch Dual Junior keep in mind the following
rules
The maximum number of layers in a LINDY CPU Switch Dual Junior cascade is
four.
You may cascade Dual Junior units with 1 or 2 KVM links. The number of KVM
links that you install defines the number of simultaneous uses that are supported.
Keep all cascade cables as short as possible. The video quality is maximised by
using the shortest possible total cable run from computer to KVM.
If you are making multiple cascade links between LINDY CPU Switch Dual Junior
then ensure that the cables are approximately the same length.
LINDY CPU Switch OSD devices may be cascaded to Dual Junior cascades but
the OSD units must always be on the lowest level of the cascade (in other words
you must not cascade a Dual Junior device off an OSD device)
LINDY CPU Switch models 32351 and 32352 may be cascaded together.
You must choose groups of cascade ports from the following table. When you
cascade using a group of ports the system will allocate the first available free port
in that group (see section 4.10 and 4.15 for more details)