MAINTENANCE

Initial inspection after 8 operating hours

!

Caution!

For the safe functioning of your sweeper, an initial inspection

must be carried out after 8 hours of operation. You should

have the inspection done by your Kärcher Customer Ser-

vice.
– inspect all bowden cables and adjust where necessary
– check that all hydraulic parts are leakproof and function

correctly

– check that the handbrake functions

Daily maintenance

– Inspect main brush roller for strapping and/or cord, etc.,

which may have wrapped round it. If so remove them.

– Check dust filters. If they are heavily contaminated with

dust, shake them out.

– Empty waste hopper.

Maintenance intervals

Keep to the maintenance schedule given in the Maintenance

booklet (5.950-535) in order to ensure that the sweeper

functions reliably and to maintain your rights under the

guarantee.
The maintenance work required must be carried out by an

authorised specialist workshop.

Maintenance tasks

!

Risk of injury

Before you work under the waste hopper in its swung-up

position, you must first secure the hopper against dropping

unintentionally by using the swing-out safety bar.

– Remove ignition key
– Pull out battery plug connection
– Open cover

Tip seat forwards. Pull cover up by the handle grip

designed for the purpose.

Checking the hydraulic system

– Carry out a visual inspection. If there is any loss of fluid

from the hydraulic unit, cylinder or hoses, call Kärcher

Customer Service.

Replacing the sealing skirts

The sealing skirts fulfil an important function. They retain the

partial vacuum in the area round the main brush roller which

is essential so that the sweeper can function properly. They

ensure that sweeping can take place without clouds of dust

being raised.
If the sealing skirts are damaged or worn out, they must be

replaced immediately.
– Park the sweeper and switch off the engine.
– Remove the retaining screws and detach the sealing

skirts.

– Fit new skirts, and align them as follows:

The side skirts should be adjusted so that they clear the

ground by 1–3 mm. Adjust the rear skirt so that it clears

the ground by 1-5 mm.

– The front skirt cannot be adjusted. Replace the skirt as

soon as you see signs of excessive wear.

– Tighten the retaining screws.

Replacing the side brush

– Park the sweeper, switch it off and make it secure.
– Raise the side brush.
– Remove the three hex-socket bolts (SW 5).

– Detach the side brush.
– Push the new side brush onto the drive pin.
– Tighten the bolts again.